The Fluke 902 FC can measure resistance in the range of 0.1 ohms to 60 kilohms. This broad range ensures it can handle both low and high resistance measurements, making it suitable for a variety of tasks, from checking motor windings to verifying circuit continuity.
Function | ||
A ac (via Jaw) | ||
Resolution | 0.1 A | |
Accuracy | 2.0% ±5 digit (45-65 Hz) | |
2.5% ±5 digit (65-400 Hz) | ||
Range | 600.0 A | |
Crest Factor (50Hz or 60Hz) | 2.5 MIN@220 A | |
> 1.4 MIN@600 A | ||
Add 2% for CF>400 A | ||
V ac | ||
Resolution | 0.1 V | |
Accuracy | 1.5% ±5 digits | |
Range | 600.0 V | |
V dc | ||
Resolution | 0.1 V | |
Accuracy | 1.5% ±5 digits | |
Range | 600.0 V | |
Ohms | ||
Resolution | 0.1/1/10 | |
Accuracy | 1% ±5 digits | |
Range | 600/6000/60.00 kΩ | |
Capacitance | ||
Resolution | 0.1/1 µF | |
Accuracy | 1% ±4 digits | |
Range | 100.0/1000 µF | |
µA | ||
Resolution | 0.1 µA | |
Accuracy | 1% ±5 digits | |
Range | 200 µA | |
Contact temperature | ||
Resolution | 0.1 C/F | |
Accuracy | 1% ±8 digits | |
Range | -40 to 400 °C (-40 °F to 752 °F) | |
Continuity beeper | ||
Beeper volume | 75 dBA nom. 15 cm. from case front | |
On threshold | <=30 Ω | |
Mechanical and General Specifications | ||
Maximum voltage between any terminal and earth ground | 1000 V | |
Battery type | 2 AA alkaline batteries, NEDA 15A, IEC LR6 | |
Temperature | Operating: -10 °C to +50 °C (14 °F to +122 °F) | |
Storage: -40 °C to +60 °C (-40 °F to +140 °F) | ||
Operating humidity | Non condensing (< 10 °C [50 °F]), ≤90 % RH (at 10 °C to 30 °C [50 °F to 86 °F]), ≤75 % RH (at 30 °C to 40 °C (86 °F to 104 °F)), ≤45 % RH (at 40 °C to 50 °C (104 °F to 122 °F)) | |
Altitude | Operating: 3,000 m (9,842 ft) | |
Storage: 12,000 m (39,370 ft) | ||
Dimensions | 230 x 83.7 x 45.4mm (9.06 x 3.30 x 1.39 in) | |
Weight (meter only) | 419 g (15 oz) | |
Safety | IEC 61010-1, Pollution Degree 2 | |
IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V | ||
IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V | ||
IP Rating | IEC 60529: IP30, non-operating | |
Radio Frequency Certification | FCC ID:T68-FBLE IC:6627A-FBLE | |
Electromagnetic Compatibility (EMC) | International: IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication Equipment) USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. | |
Temperature coefficients | Add 0.1 × specified accuracy for each degree C above 28 °C or below 18 °C |
00971 (04) 447 6031
Deira Creek, Radisson Blu Hotel, Plaza Bldg, 4th , 403 - Dubai UAE