Brand: Fluke
Power-on Test Range: 90 V to 264 V
Power-on Test Accuracy at 50 Hz: ±(2% + 3 counts)
Power-on Test Resolution : 1 V
Maximum Input Mains Voltage: 264 V
Earth Bond Test range: 0.2 Ω to 1.99 Ω
Earth Bond Test Accuracy : ±(5 % + 4 counts
Earth Bond Test Resolution: 0.01 Ω
Insulation Test Range: 0 to 299 MΩ
Insulation Test Accuracy : ±(5% + 2 counts) from 0.1 to 300 MΩ
Insulation Test Resolution: 0.01 MΩ (0 to 19.99 MΩ), 0.1 MΩ (20 to 199.9 MΩ), 1 MΩ (200 to 299 MΩ)
Dimentions: 200 x 275 x 114 mm
Weight: 3.13 kg
Power : 230 V +10 % -15 %, 50 Hz ±2 Hz
Operating temperature: 0 °C to +40 °C
Storage temperature: -10 °C to +60 °C
Altitude : 0 m up to 2000 m

Fluke 6200-2 UK Perfect Portable Appliance Tester Starter Kit

The Fluke 6200-2 UK Portable Appliance Tester Starter Kit is a comprehensive solution designed to meet the demands of electrical safety testing. This kit is a reliable choice for professionals who need to perform Portable Appliance Testing (PAT) efficiently. In this article, we explore the key features and advantages that make the Fluke 6200-2 UK Starter Kit an essential tool for maintaining electrical safety.

Key Features

The Fluke 6200-2 UK Portable Appliance Tester Starter Kit boasts a range of features crucial for effective PAT. With the ability to test appliances at 230V, this kit ensures a thorough evaluation of electrical equipment. It provides a reliable means of checking for faults, ensuring compliance with safety standards. The kit's robust design and functionality make it a go-to choice for professionals in various industries.

Comprehensive Testing
One of the standout features of the Fluke 6200-2 UK Starter Kit is its ability to conduct comprehensive testing on appliances. From measuring earth bond resistance to insulation resistance and leakage current, this kit provides a thorough examination of the safety aspects of electrical devices. This comprehensive testing capability contributes to creating a secure working environment by identifying potential hazards.
Versatility and Ease of Use
The Fluke 6200-2 UK Starter Kit is known for its versatility and user-friendly design. The kit comes equipped with everything needed for efficient PAT, making it suitable for both seasoned professionals and those new to electrical testing. Its intuitive interface and straightforward operation streamline the testing process, ensuring accurate results without unnecessary complexity.
Professional Bundled Kit
The Fluke 6200-2 UK PAT Tester is often available in professional bundles, enhancing its utility. These bundles may include additional accessories and software, empowering users with a complete solution for their PAT needs. This bundled approach simplifies the procurement process and ensures that users have all the tools required for effective electrical safety testing.
The Fluke PAT Tester Starter Kit stands as a reliable and efficient solution for professionals engaged in electrical safety testing. With its comprehensive testing capabilities, user-friendly design, and the option for professional bundles, this kit ensures that electrical appliances are thoroughly examined for safety compliance. Investing in the Fluke 6200-2 UK Starter Kit is a proactive step toward creating a secure environment and adhering to industry standards.

Fluke 6200-2 UK Kit Specifications

Test specifications The accuracy specification for the display range is defined as ±(%reading + digit counts) at 23 °C ±5 °C, ≤75% RH.
Between 0 °C and 18 °C and between 28 °C and 40 °C, accuracy specifications may degrade by 0.1 x (accuracy specification) per °C.
The measurement range meets the service operating errors specified in EN61557-1: 1997, EN61557-2: 1997, EN61557-4: 1997, EN61557-6: 1997, DIN VDE0404-2.
Power-on test The test indicates reversed L-N, missing PE, and measures the mains voltage and frequency.
Display range 90 V to 264 V
Accuracy at 50 Hz ±(2% + 3 counts)
Resolution 1 V
Input impedance > 1 MΩ // 2.2 nF
Maximum input mains voltage 264 V
Earth bond test (R pe) Display Range 0 to 19.99 Ω
Accuracy (after bond test zeroing) ±(2.5% + 4 counts)
Resolution 0.01 Ω
Test current 200 mA AC -0% +40% into 1.99 Ω
25 A AC ±20% into 25 mΩ at 230 V
Open circuit voltage > 4 V AC, < 24 V AC
Bond test zeroing can subtract up to 1.99 Ω
Insulation test (R iso) Display range 0 to 299 MΩ
Accuracy ±(5% + 2 counts) from 0.1 to 300 MΩ
Resolution 0.01 MΩ (0 to 19.99 MΩ)
0.1 MΩ (20 to 199.9 MΩ)
1 MΩ (200 to 299 MΩ)
Test voltage 500 V DC -0% + 10% at 500 kΩ load
Test current > 1 mA at 500 kΩ load, < 15 mA at 0 Ω
Auto discharge time < 0.5 s for 1 μF
Max. capacitive load Operational up to 1 μF
Touch current test Display range 0 to 1.99 mA AC
Accuracy ±(4% + 2 counts)
Resolution 0.01 mA
Internal resistance (via probe) 2 kΩ
Measuring method Probe*
Substitute leakage current test Display range 0 to 19.99 mA AC
Accuracy ±(2.5% + 3 counts)
Resolution 0.01 mA
Test Voltage 100 V AC ±20%
Load/leakage test: load current Display range 0 A to 13 A
Accuracy ±(4% + 2 counts)
Resolution 0.1 A*
Load/leakage test: load power Display range 230 V Mains 0.0 VA to 3.2 kVA
Accuracy ±(5% + 3 counts)
Resolution 1 VA (0 to 999 VA), 0.1 kVA (>1.0 kVA)*
Load/leakage test: leakage current Display range 0 to 19.99 mA
Accuracy ±(4% + 4 counts)
Resolution 0.01 mA*
PELV test Accuracy at 50 Hz ±(2% + 3 counts)
Overload protection 300 V rms
Warning threshold 25 V rms
*The appliance under test is energized at mains potential.
Environmental specifications
Operating temperature 0 to 40 °C
Relative humidity Non condensing <10 °C
95% from 10 to 30 °C
75% from 30 to 40 °C
Safety specifications
Safety rating Complies with EN61010-1 3rd edition
CAT II, 300 V, pol 2
Mechanical and general specifications
Size (L x W x H) 200 x 275 x 114 mm
Weight 3.13 kg
Power supply 230 V +10% -15%, 50 Hz ±2
Power consumption (tester) 13 W typical (idle)
60 W max. during 25A Bond test
Storage Temperature -10 to 60 °C
Corrosion 70 °C @ 95% RH for 5 days max.
Operating altitude 0 up to 2000 m
Sealing IP-40 (enclosure), IP-20 (connectors)
EMC Complies with EN61326-1, portable
EMI Immunity 3 V/m
Save this product for later
Share this product with your friends
Fluke 6200-2 UK Perfect Portable Appliance Tester Starter Kit
Share by:
document.addEventListener("DOMContentLoaded", function() { const observer = new MutationObserver(function() { const products = document.querySelectorAll(".details-product-price__value.ec-price-item.notranslate"); products.forEach(function(priceElement) { if (parseFloat(priceElement.textContent) === 0) { priceElement.textContent = "Call for Best Price\n00971(04) 447 6031\n00971(04) 344 9868"; } }); }); observer.observe(document.body, { childList: true, subtree: true }); });