مطلوب تأكيد نهائي من الدعم. بمجرد تقديم طلبك، يرجى انتظار التأكيد النهائي من الشركة. ( 97144476031)
Fluke 116/62 MAX+ Technician’s Combo Kit
0.00 AED
In stock
Product Details
Brand:
Fluke
AC Voltage Range:
600.0 mV / 0.1 mV
DC Voltage Range:
600.0 mV / 0.1 mV
AC Current Range:
10 A (20 A for 30 seconds maximum)
DC Current Range:
10 A (20 A for 30 seconds maximum)
AC Voltage Overload Protection:
6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
DC Voltage Overload Protection:
6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Resistance Range:
600.0 Ω / 0.1 Ω, 6.000 kΩ / 0.001 kΩ, 60.00 kΩ / 0.01 kΩ, 600.0 kΩ / 0.1 kΩ, 6.000 MΩ / 0.001 MΩ
Capacitance Range:
1000 nF / 1 nF, 10.00 μF / 0.01 μF, 100.0 μF / 0.1 μF, 9999 μF / 1 μF, 100 μF to 1000 μF
Frequency Range :
99.99 Hz / 0.01 Hz, 999.99 Hz / 0.1 Hz, 9.999 Hz / 0.001 Hz, 50.00 Hz / 0.01 Hz
Conductance Range:
60.00 nS
Diode test:
2.000 V
Temperature Range:
-30°C to 650°C (-22°F to 1202°F)
Power:
AA battery
Dimension:
Fluke 116 Multimeter: 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in), Fluke 62 MAX+: 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in)
Weight:
Fluke 116 Multimeter: 550 g, Fluke 62 MAX+: 255 g (8.99 oz)
Continuity buzzer:
600 Ω / 1 Ω
Applicable standards:
EN/IEC 61010-1: 2001, FDA and EN 60825-1 Class II
Fluke 116/62 MAX+ Technician’s Combo Kit
The Fluke 116/62 MAX+ Technician’s Combo Kit stands as a testament to the brand's commitment to providing high-quality, reliable tools for professionals in the HVAC and electrical fields. This article delves into the features and applications of this combo kit, highlighting its design and functionality tailored for technicians who demand precision and durability in their instruments.
Fluke 116 HVAC Features
The Fluke 116 HVAC Multimeter is designed with features that make it an indispensable tool for HVAC technicians. It includes a built-in thermometer specifically for HVAC applications, allowing for quick and accurate temperature measurements. The multimeter also offers microamps testing capability, essential for diagnosing flame sensors in heating systems. Its low input impedance feature is crucial for preventing false readings caused by ghost voltage, a common issue in electrical troubleshooting. Additionally, the Fluke 116 is equipped with a large white LED backlight, enhancing visibility in poorly lit environments.
Features of the Fluke 62 MAX+ Infrared Thermometer
The Fluke 62 MAX+ Infrared Thermometer complements the multimeter by providing non-contact temperature measurements. It can measure temperatures ranging from -30 °C to 650 °C (-22 °F to 1202 °F), with remarkable accuracy. The thermometer is IP54 rated, indicating its resistance to water and dust, making it suitable for use in various environmental conditions. Its rugged design is capable of withstanding a 3-meter drop, ensuring durability. The dual lasers of the Fluke 62 MAX+ aid in precisely identifying the measurement area, adding to its functionality.
Applications in HVAC and Electrical Work
The combination of the Fluke 116 HVAC Multimeter and the Fluke 62 MAX+ Infrared Thermometer in the Fluke 116/62 MAX+ Technician’s Combo Kit makes it an essential toolset for HVAC professionals and electricians. The built-in thermometer and microamps testing capability of the multimeter are particularly useful for troubleshooting HVAC systems, including checking temperatures and diagnosing issues with flame sensors. The infrared thermometer's ability to quickly measure surface temperatures without contact is invaluable for identifying overheating components or checking temperature differentials in HVAC systems.
Design and Ergonomics
Both the Fluke 116 HVAC Multimeter and the Fluke 62 MAX+ Infrared Thermometer are designed with the user in mind. Their compact sizes and lightweight designs make them easy to carry and use throughout the day. The multimeter's large white LED backlight and the thermometer's dual lasers are examples of how Fluke has integrated features to enhance usability and accuracy in measurements.
Fluke 116/62 MAX+ Technician’s Combo Kit Specifications:
Maximum voltage between any terminal and earth ground | 600 V | |
Surge protection | 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 | |
Display | 6,000 counts, updates 4 per second | |
Bar graph | 33 segments, updates 32 per second | |
Operating Temperature | -10°C to +50°C | |
Storage Temperature | -40°C to +60°C | |
Battery type | 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 | |
Battery Life | 400 hours typical, without backlight | |
Accuracy Specifications | ||
DC millivolts | Range/Resolution | 600.0 mV / 0.1 mV |
Accuracy | ±([% of reading] + [counts]): 0.5% + 2 | |
DC volts | Range/Resolution | 6.000 V / 0.001 V |
60.00 V / 0.01 V | ||
600.00 V / 0.1 V | ||
Accuracy | ±([% of reading] + [counts]): 0.5% + 2 | |
Auto volts | Range | 600.0 V / 0.1 V |
Accuracy | 2.0% + 3 (DC, 45 Hz to 500 Hz) | |
4.0% + 3 (500 Hz to 1 kHz) | ||
AC millivolts1 True RMS | Range | 600.0 mV / 0.1 mV |
Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) | |
2.0% + 3 (500 Hz to 1 kHz) | ||
AC volts1 True RMS | Range/Resolution | 6.000 V / 0.001 V |
60.00 V / 0.01 V | ||
600.0 V / 0.1 V | ||
Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) | |
2.0% + 3 (500 Hz to 1 kHz) | ||
Continuity | Range | 600 Ω / 1 Ω |
Accuracy | Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer. | |
Ohms | Range/Resolution | 600.0 Ω / 0.1 Ω |
6.000 kΩ / 0.001 kΩ | ||
60.00 kΩ / 0.01 kΩ | ||
600.0 kΩ / 0.1 kΩ | ||
6.000 MΩ / 0.001 MΩ | ||
Accuracy | 0.9% + 1 | |
Range/Resolution | 40.00 MΩ / 0.01 MΩ | |
Accuracy | 1.5% + 2 | |
Diode Test | Range/Resolution | 2.000 V / 0.001 V |
Accuracy | 0.9% + 2 | |
Capacitance | Range/Resolution | 1000 nF / 1 nF |
10.00 μF / 0.01 μF | ||
100.0 μF / 0.1 μF | ||
9999 μF / 1 μF | ||
100 μF to 1000 μF | ||
Accuracy | 1.9% + 2 | |
Range/Resolution | > 1000 μF | |
Accuracy | 5% + 20% | |
LoZ capacitance | Range | 1 nF to 500 μF |
Accuracy | 10% + 2 typical | |
Temperature2 (Type-K thermocouple) | Range/Resolution | -40°C to 400°C / 0.1°C |
Accuracy2 | 1% + 10 | |
Range/Resolution | -40°F to 752°F / 0.2°F | |
Accuracy2 | 1% + 18 | |
AC μamps true-rms (45 Hz to 500 Hz) | Range/Resolution | 600.0 μA / 0.1 μA |
Accuracy | 1.0% + 2 | |
DC μamps | Range/Resolution | 600.0 μA / 0.1 μA |
Accuracy | 1.0% + 2 | |
Hz (V or A input)2 | Range/Resolution | 99.99 Hz / 0.01 Hz |
999.99 Hz / 0.1 Hz | ||
9.999 Hz / 0.001 Hz | ||
50.00 Hz / 0.01 Hz | ||
Accuracy | 0.1% + 2 | |
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. | ||
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. | ||
• Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current. | ||
• Temperature Range/Resolution: -40°F to 752°F / 0.2°F. | ||
Mechanical and General Specifications | ||
Size | 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) | |
Weight | 550 g | |
Warranty | 3 years | |
Fluke 62 MAX+ Infrared Thermometer | ||
Specifications | ||
Temperature range | -30°C to 650°C (-22°F to 1202°F) | |
Accuracy | ±1.0°C or ±1.0% of reading, whichever is greater | |
-10°C to 0°C: ±2.0 | ||
-30°C to -10°C: ±3.0 | ||
Response time (95%) | < 300 ms (95% of reading) | |
Spectral response | 8 to 14 microns | |
Emissivity | 0.10 to 1.00 | |
Optical resolution | 12:1 (calculated at 90% energy) | |
Display resolution | 0.1°C (0.2°F) | |
Repeatability of readings | ±0.5% of reading or <±0.5°C (1°F), whichever is greater | |
Power | AA battery | |
Battery life | 8 hours with laser and backlight on | |
Physical Specifications | ||
Weight | 255 g (8.99 oz) | |
Size | 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in) | |
Operating temperature | 0°C to 50°C (32°F to 122°F) | |
Storage temperature | -20°C to 60°C (-4°F to 140°F), (without battery) | |
Operating humidity | 10% to 90% RH non-condensing at 30°C (86°F) | |
Operating altitude | 2000 meters above mean sea level | |
Storage altitude | 12,000 meters above mean sea level | |
IP rating | IP 54 per IEC 60529 | |
Drop test | 3 meters | |
Vibration and shock | IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms | |
EMC | EN 61326-1:2006 EN 61326-2:2006 | |
Standards and agency approval | Compliance | EN/IEC 61010-1: 2001 |
Laser safety | FDA and EN 60825-1 Class II |
Save this product for later
Fluke 116/62 MAX+ Technician’s Combo Kit
Display prices in:
AED