Welcome to Uazon! Your one-stop shop for all measuring equipment.

Product Suggestions

Uni-T

UT890C True RMS Digital Multimeter - Professional Electrical Measurement Tool

76 views
In stock
Delivery
  • True RMS digital multimeter with 6000-count display

  • Measures voltage (1000V DC, 750V AC), current (20A), resistance (60MΩ)

  • Temperature measurement: -40°C to 1000°C

  • Capacitance, frequency, continuity, and diode testing

  • Non-contact voltage detection (NCV) with acousto-optic alert

  • CAT II 1000V / CAT III 600V safety rating

  • MAX/MIN recording, data hold, and REL functions

  • Professional tool for electrical, HVAC, and automotive diagnostics

Added to compare list
Order above 500 AED = Free Delivery
Delivery by * within UAE. When you order in
This item will be delivered by .
Want it Tomorrow?
Select Click & Collect on checkout within the next
We are not Supporting COD Payments Terms Outside UAE
Secure Transaction
This item is eligible for return
Online support
24/7 Support
Original Products
quality guarantee
Fast Delivery
Fastest delivery ever!
Online payment
fast and safe
secure and live track
fast and safe
Description

About this model

The UT890C True RMS Digital Multimeters represent professional-grade electrical testing instruments engineered for electricians, automotive technicians, HVAC professionals, and electronics enthusiasts. This advanced digital multimeter features True RMS technology for accurate measurements on non-sinusoidal waveforms, 6000-count high-resolution display, and comprehensive testing functions including voltage, current, resistance, capacitance, frequency, and temperature measurement. With CAT II 1000V and CAT III 600V safety ratings, the UT890C delivers reliable performance for demanding residential, commercial, and industrial electrical diagnostics across UAE applications.

Advanced Features of UT890C Digital Multimeter

True RMS measurement technology ensures accurate readings on distorted waveforms from variable frequency drives, inverters, switching power supplies, and modern electronic equipment. Unlike average-responding meters that produce significant errors with non-linear loads, the UT890C calculates true root mean square values for professional-grade precision. The 6000-count display provides superior resolution compared to standard 2000-count meters, showing measurements with enhanced detail for critical diagnostics.

The UT890C measures DC voltage up to 1000V with ±0.5% accuracy, AC voltage to 750V, DC and AC current to 20A, resistance to 60 megohms, and capacitance to 100 millifarads. Temperature measurement ranges from -40°C to 1000°C, making the UT890C uniquely versatile for HVAC diagnostics, industrial equipment monitoring, and automotive testing. Frequency measurement extends to 9.999 MHz for testing oscillators, signal generators, and high-frequency circuits.

Safety and Convenience Functions

Non-contact voltage detection (NCV) with acousto-optic indication alerts users to live wires before physical contact, enhancing workplace safety. Fuse blowing alarm warns when current exceeds safe limits, protecting both instrument and operator. High voltage false detection at 1000Vrms prevents dangerous measurement errors. Over-current alarm activates at 20A or greater, while low battery indication ensures you never lose power during critical measurements.

Data hold freezes displayed readings for convenient recording. MAX/MIN functions track extreme values during monitoring sessions. REL (relative mode) establishes reference points for comparative measurements. The 30-second backlight illuminates the display in dimly lit electrical panels and confined spaces. Automatic power-off after 15 minutes conserves battery life during extended field operations.

Applications for UT890C True RMS Multimeter

  • Residential and commercial electrical troubleshooting
  • Industrial equipment maintenance and diagnostics
  • HVAC system electrical testing and temperature monitoring
  • Automotive electrical system repair and diagnostics
  • Solar panel installation voltage and current verification
  • Electronics repair and component testing
  • Motor and pump electrical performance analysis
  • Power distribution panel testing and verification
  • Appliance repair voltage and resistance measurements
  • Generator and UPS system diagnostics
  • Building automation system troubleshooting
  • Manufacturing quality control testing
  • Laboratory electronics development and testing
  • Battery system voltage and current monitoring

Technical Specifications UT890C Multimeter

The robust construction measures 183mm x 88mm x 56mm with 346g weight, providing professional durability while maintaining portability. Two 1.5V batteries power the device with efficient energy management. The red and grey housing offers professional aesthetics with ergonomic design for comfortable single-handed operation. Operating temperature range of 0°C to 40°C accommodates most field conditions.

Manual ranging provides precise control over measurement scales, while continuity testing with audible beeper enables efficient circuit verification. Diode testing verifies semiconductor junction functionality. The hFE function measures transistor gain for electronics repair. Current mode memory retains AC/DC selection for streamlined operation. CAT II 1000V and CAT III 600V safety certifications ensure safe operation in demanding electrical environments.

Why Buy UT890C True RMS Multimeter from UAZON.AE

UAZON.AE provides genuine UT890C True RMS Digital Multimeters with complete accessories, user manual, and full manufacturer warranty throughout Dubai, Abu Dhabi, Sharjah, and all UAE Emirates. Our competitive pricing delivers professional electrical testing equipment at exceptional value for contractors, technicians, and engineers. Fast shipping ensures your multimeter arrives ready for immediate deployment in gift box packaging. Expert customer support assists with measurement techniques and safety protocols for UAE electrical standards.

How to Use UT890C Digital Multimeter

Install two 1.5V batteries in the compartment. Connect test leads to appropriate terminals: COM for common, VΩ for voltage/resistance/frequency, and A for current measurements. Select the measurement function and range using the rotary dial. For voltage measurements, touch probes to circuit points. For current measurements, break the circuit and connect the meter in series. For resistance, ensure power is off before testing. Use the NCV function to detect live voltage without contact by bringing the meter close to conductors. Press HOLD to freeze readings, MAX/MIN to track extremes, and REL for relative measurements. The backlight activates automatically in low-light conditions.

Specification

Specifications of UT890 True RMS Digital Multimeters

Specification Range UT890C UT890D+
DC Voltage 600mV/6V/60V/600V/1000V ±(0.5%+2) ±(0.5%+2)
AC Voltage 6V/60V/600V/750V ±(0.8%+3) ±(0.8%+3)
ACV Frequency 10Hz~10kHz ±(0.1%+5) ±(0.1%+5)
DC Current 60uA//600uA/6mA/60mA/600mA/20A ±(0.8%+8) ±(0.8%+8)
AC Current 60uA/600uA/6mA/60mA/600mA/20A ±(1%+12) ±(1%+12)
Resistance 600Ω/6kΩ/60kΩ/600kΩ/6MΩ/60MΩ ±(0.8%+3) ±(0.8%+3)
Capacitor 6.000nF/60.00nF/600.0nF/6.000μF/60.00μF/
600.0μF/6.000mF/60.00mF/100.0mF
±(3%+10) ±(3%+10)
Frequency 9.999Hz~9.999MHz ±(1.0%+5) ±(1.0%+5)
Temperatue –40℃~1000℃/–40°F~1832°F ±(1.5%+5)  
Fetures
Display Count   6000 6000
Manual Range  
NCV  
hFE  
Diode Test  
Continuity Test  
Live    
True RMS  
Fuse blowing alarm  
Acousto-optic indication(NCV/continuity)  
High voltage false detection 1000Vrms
Current (AC/DC) mode memory  
Over-current alarm ≥20A
Low Battery Indication ≤2.5V
Data Hold  
REL  
Max/Min V 、A
Auto  Power Off 15Min
Back light 30s
Operation Temperature 0℃~40℃
Safety CAT II 1000V/CAT III 600V
General Characteristics
Power 1.5V x 2
Product color Red and Gray
Product Net Weight 346g
Product Size 183mm x 88mm x 56mm
Standard Individual Packing Gift Box, Manual
Standard Quantity Per Carton 40pcs
Standard carton measurement 690mm x 450mm x 340mm
Standard carton gross weight 23Kg
Downloads
FAQs & How To

UT890C FAQs

True RMS accurately measures AC voltage and current on distorted waveforms from non-linear loads, providing more accurate readings than average-responding meters when testing modern electronic equipment.
The UT890C measures DC voltage up to 1000V and AC voltage up to 750V, with safety ratings of CAT II 1000V and CAT III 600V for safe operation in various electrical environments.
Yes, the UT890C includes temperature measurement from -40°C to 1000°C with ±1.5% accuracy, ideal for HVAC diagnostics, industrial equipment monitoring, and thermal troubleshooting.
The UT890C includes temperature measurement capability that the UT890D+ lacks, while the UT890D+ features a live wire detection function not present on the UT890C.
The UT890C is rated CAT II 1000V and CAT III 600V, certified for safe measurements in distribution panels, industrial installations, and commercial electrical systems.
Reviews (7)
Add a review
/ 5
Related Products
Added to compare list
Added to compare list
Added to compare list
Added to compare list
Added to compare list
Added to compare list
Added to compare list
Added to compare list