Welcome to Uazon! Your one-stop shop for all measuring equipment.

Product Suggestions

Megger
Order Number: BS-59007

Megger TXL870 Extra Load Units For Torkel Battery Test System

35 views
Delivery
  • Maximum voltage capability up to 480 V
  • High current capacity with 300 A peak load
  • Peak power ratings from 8.3 kW to 25.5 kW across models
  • Series includes models TXL830 to TXL890
Added to compare list
Order above 500 AED = Free Delivery
Delivery by * within UAE. When you order in
This item will be delivered by .
Want it Tomorrow?
Select Click & Collect on checkout within the next
We are not Supporting COD Payments Terms Outside UAE
Secure Transaction
This item is eligible for return
Online support
24/7 Support
Original Products
quality guarantee
Fast Delivery
Fastest delivery ever!
Online payment
fast and safe
secure and live track
fast and safe
Description

About this model

Megger TXL870: High-Current Battery Testing for Mission-Critical Power Systems

Ensuring the reliability of backup power systems is a non-negotiable requirement for industries where downtime is not an option. The Megger TXL870 Extra Load Unit is engineered specifically to address this need by expanding the capabilities of the TORKEL battery test systems. Designed to deliver higher load currents for demanding discharge tests, this unit is a vital component for conducting thorough constant current or constant power assessments. Whether you are managing a data center, a telecommunications hub, or a utility grid, the Megger TXL870 provides the robust performance required to validate battery health under severe stress conditions.

When considering the investment in reliable testing equipment, the Megger TXL870 Price reflects its advanced engineering and durability. For facility managers and electrical engineers, the ability to simulate real-world load scenarios is critical. This extra load unit allows for precise control over discharge rates, ensuring that batteries can handle peak loads during emergencies. If you are looking to Buy Megger TXL870, understanding its integration with the TORKEL system is key to maximizing your testing efficiency.

Technical Features and Field Applications of the Megger TXL870

The Megger TXL870 is part of the TXL series, which consists of extra load units specifically designed to provide higher load currents for constant current or constant power tests. When paired with the TORKEL unit, these loads create a comprehensive system capable of discharging batteries with currents reaching several kiloamperes (kA). This capability is essential for large-scale battery systems found in critical infrastructure. The unit connects directly to the battery under test, while the TORKEL unit measures the total current using a clamp-on ammeter, ensuring accurate and safe readings without interrupting the circuit.

The synergy between the TORKEL and the TXL870 allows for a modular approach to battery testing. As your power requirements grow, you can integrate additional TXL units to increase the load capacity. This scalability makes the Megger TXL870 an attractive option for facilities planning future expansions. When you evaluate the Megger TXL870 Price, consider the long-term value of a system that grows with your infrastructure. For those ready to secure their power reliability, buying the Megger TXL870 is a strategic investment in operational continuity.

Key Features and Operational Benefits

The design of the Megger TXL870 focuses on delivering high performance while maintaining ease of use in field environments. Below are the core features that define this extra load unit and how they translate into practical benefits for the operator.

  • Higher Load Currents for Concurrent Power Tests: The unit is engineered to handle substantial current loads, allowing for simultaneous testing of multiple battery strings or high-capacity cells. This feature reduces testing time and increases throughput, making it ideal for large-scale operations where efficiency is paramount.
  • Discharging Process Controlled by a TORKEL Unit: Integration with the TORKEL system ensures that the discharge process is automated and precise. The TORKEL unit regulates the load, maintaining constant current or constant power throughout the test, which eliminates manual adjustments and reduces the risk of human error.
  • Direct Connection to the Battery Under Test: The TXL870 connects directly to the battery terminals, providing a stable and secure load path. This direct connection ensures that the test results are accurate and representative of the battery's true performance under load.

Integration with TORKEL Systems for Enhanced Testing

The Megger TXL870 is not a standalone device; it is a critical extension of the TORKEL battery test system. By connecting the extra load unit directly to the battery, users can achieve currents that would be impossible with the TORKEL unit alone. The TORKEL unit acts as the brain of the operation, measuring the total current via a non-intrusive clamp-on ammeter. This setup ensures that the battery is discharged safely and accurately, providing data that is essential for compliance and maintenance planning.

For procurement teams, the decision to Buy Megger TXL870 should be based on the need for high-current testing capabilities. The Megger TXL870 Price is competitive when compared to the cost of downtime caused by battery failure. By integrating this unit into your existing TORKEL setup, you create a versatile testing platform that can handle the most demanding discharge scenarios

Specification

Load Section

Model Voltage (DC) max. Current max. Power max.
TXL830 28 V 300 A 8.3 kW
TXL850 56 V 300 A 16.4 kW
TXL865 260 V (98 A max) 117 A 25.5 kW
TXL870 280 V (56 A max) 112 A 15.8 kW
TXL890 480 V (32 A max) 62 A 15.4 kW

Internal Resistance (3-Position Selector)

Model Position 1 Position 2 Position 3
TXL830 0.275 Ω 0.138 Ω 0.092 Ω
TXL850 0.55 Ω 0.275 Ω 0.184 Ω
TXL865 2.65 Ω 5.05 Ω 0.12 Ω
TXL870 4.95 Ω 2.48 Ω 1.24 Ω
TXL890 14.10 Ω 7.05 Ω 3.52 Ω

Maximal Currents (3-Position Selector)

1) The data examples apply to lead batteries.

Position 1

Position Model Max Voltage Current Voltage Cells / Cell Voltage
Position 1 TXL830 28 V max 100 A 27.6 V 12 / 2.3 V
Position 1 TXL830 28 V max 78.5 A 21.6 V 12 / 1.8 V
Position 1 TXL850 56 V max 100 A 55.2 V 24 / 2.3 V
Position 1 TXL850 56 V max 78.5 A 43.2 V 24 / 1.8 V
Position 1 TXL865 260 V max 93.7 A 248.4 V 108 / 2.3 V
Position 1 TXL865 260 V max 73.4 A 194.4 V 108 / 1.8 V
Position 1 TXL870 280 V max 50.1 A 248.4 V 108 / 2.3 V
Position 1 TXL870 280 V max 39.2 A 194.4 V 108 / 1.8 V
Position 1 TXL890 480 V max 32.3 A 469.2 V 204 / 2.3 V
Position 1 TXL890 480 V max 26.0 A 367.2 V 204 / 1.8 V

Position 2

Position Model Max Voltage Current Voltage Cells / Cell Voltage
Position 2 TXL830 28 V max 200 A 27.6 V 12 / 2.3 V
Position 2 TXL830 28 V max 156 A 21.6 V 12 / 1.8 V
Position 2 TXL850 56 V max 200 A 55.2 V 24 / 2.3 V
Position 2 TXL850 56 V max 156 A 43.2 V 24 / 1.8 V
Position 2 TXL865 260 V max 49.2 A 248.4 V 108 / 2.3 V
Position 2 TXL865 260 V max 38.5 A 194.4 V 108 / 1.8 V
Position 2 TXL870 280 V max 50.1 A 124.2 V 54 / 2.3 V
Position 2 TXL870 280 V max 39.2 A 97.2 V 54 / 1.8 V
Position 2 TXL890 480 V max 35.2 A 248.4 V 108 / 2.3 V
Position 2 TXL890 480 V max 27.8 A 194.4 V 108 / 1.8 V

Position 3

Position Model Max Voltage Current Voltage Cells / Cell Voltage
Position 3 TXL830 28 V max 300 A 27.6 V 12 / 2.3 V
Position 3 TXL830 28 V max 235 A 21.6 V 12 / 1.8 V
Position 3 TXL850 56 V max 300 A 55.2 V 24 / 2.3 V
Position 3 TXL850 56 V max 235 A 43.2 V 24 / 1.8 V
Position 3 TXL865 14 V max 115 A 13.8 V 6 / 2.3 V
Position 3 TXL865 14 V max 90 A 10.8 V 6 / 1.8 V
Position 3 TXL870 140 V max 100 A 124.2 V 54 / 2.3 V
Position 3 TXL870 140 V max 74.8 A 97.2 V 54 / 1.8 V
Position 3 TXL890 250 V max 70.5 A 248.4 V 108 / 2.3 V
Position 3 TXL890 250 V max 55.2 A 194.4 V 108 / 1.8 V
Downloads
FAQs & How To

FAQs

It is an expansion load unit designed to increase the discharge capacity of compatible Megger Torkel battery test systems.
Extra load units allow accurate discharge testing of larger battery banks by increasing total load capacity.
Yes, it is commonly used in industrial and infrastructure projects where reliable battery performance validation is required.
You can buy it from uazon.ae, an authorized distribiutor offering project and service support.

How To

Short summary for search results.

Estimated Time: PT15M

Read safety notes and gather what you need.
Follow the instructions included with your order.
Reviews (8)
Add a review
/ 5
Related Products
Added to compare list
Added to compare list
Added to compare list
Added to compare list
Added to compare list
Added to compare list
Added to compare list
Added to compare list
NEXT
PREV