  • Measurement Range: 20 m to 1280 km with 0.1 m resolution and ± 0.2% accuracy
  • Performance: Up to 400 MHz sample rate with 80 dB dynamic range
  • Pulse Specs: 20 ns to 10 μs width with 30 V to 160 V amplitude
  • Connectivity: 50 Ω output impedance with adjustable compensation
Order above 500 AED = Free Delivery
Delivery by * within UAE. When you order in
This item will be delivered by .
Want it Tomorrow?
Select Click & Collect on checkout within the next
We are not Supporting COD Payments Terms Outside UAE
Secure Transaction
This item is eligible for return
Online support
24/7 Support
Original Products
quality guarantee
Fast Delivery
Fastest delivery ever!
Online payment
fast and safe
secure and live track
fast and safe
Description

About this model

Revolutionizing Power Cable Diagnostics with the Megger Teleflex VX

In the demanding world of high-voltage infrastructure, the reliability of power cable networks is non-negotiable. Technicians and engineers require tools that not only identify faults but do so with precision and speed. The Megger Teleflex VX reflectometer emerges as a significant advancement in Megger’s renowned Teleflex series, specifically engineered to elevate the efficiency of power cable fault location. By encapsulating cutting-edge technology tailored for complex diagnostics, the Teleflex VX sets a new standard for accuracy in the field. For procurement teams looking to secure the latest in cable testing innovation, the Buy Megger Teleflex VX option offers immediate access to these superior capabilities.

This latest model represents a leap forward in hardware performance, offering significantly improved parameters compared to its predecessors. When evaluating the Megger Teleflex VX price, it is essential to consider the value derived from its enhanced operational range and measurement resolution. Designed for extensive power cable networks, this reflectometer ensures that maintaining system reliability is both streamlined and effective. Whether you are upgrading your current equipment or expanding your diagnostic fleet, the Teleflex VX stands as the best price investment for long-term field efficiency.

Technical Features and Field Applications of the Megger Teleflex VX

The core of the Teleflex VX’s performance lies in its advanced hardware architecture. This section explores the technical specifications that drive its superior field applications. Unlike older models, the Teleflex VX is equipped with a higher sampling rate, wider pulse width, and increased pulse amplitude. These enhancements are not merely numbers on a datasheet; they translate directly to a device capable of operating over distances up to 1000 km with exceptional clarity.

By expanding the operational range, the reflectometer provides superior resolution and markedly improved measurement capabilities. This makes the Teleflex VX an ideal tool for maintaining the reliability of vast power cable infrastructures. For teams requiring the highest level of precision, the decision to Buy Megger Teleflex VX is supported by its ability to handle complex fault location scenarios with ease. The following technical highlights illustrate how these specifications are applied in real-world scenarios:

  • Extended Operational Range: With a range capability reaching up to 1280 km (at v/2 = 80 m/µs), the device handles everything from short utility runs to long-distance transmission lines without compromising signal integrity.
  • Adjustable Pulse Parameters: The pulse width ranges from 20 ns to 10 µs, while the pulse amplitude adjusts from 30 V to 160 V, allowing technicians to customize the signal for specific cable types and fault impedances.
  • High-Speed Sampling: Featuring a sample rate of up to 400 MHz (true sample rate), the reflectometer captures detailed waveform data, essential for pinpointing faults with millimeter precision.
  • Enhanced Resolution: The device offers a resolution of 0.1 m at standard velocities, ensuring that even the most subtle fault reflections are visible and analyzable.

ProRange Function for Enhanced Reflection Visibility

One of the standout features of the Teleflex VX is the ProRange function, which facilitates range-based gain adjustments. In complex cable networks, distant reflections often appear weaker than those from shorter distances, making diagnosis difficult. This innovative feature allows distant reflections to be displayed with the same amplitude as those from shorter distances. By normalizing the display, the Teleflex VX enhances the accuracy and clarity of reflectometer readings, ensuring that no fault goes unnoticed.

This functionality is crucial when working with long cable lengths, as it ensures that all segments of the cable are equally represented in the diagnostics, regardless of their distance from the source. For engineers prioritizing diagnostic clarity, the Megger Teleflex VX price reflects the inclusion of this proprietary technology. The ProRange system eliminates the guesswork involved in gain adjustments, providing a consistent visual field for analysis. When you Buy Megger Teleflex VX, you are investing in a tool that simplifies the most challenging long-distance measurements.

Data Management and Transfer Capabilities

Efficiency in fault location extends beyond the field measurements to data handling and reporting. The Teleflex VX excels in data management and transfer, offering flexible options for saving and sharing critical diagnostic information. Measurement data can be conveniently transferred via a USB drive, supporting both the MeggerBook Cable software format and PDF files. This versatility ensures that data is compatible with various analysis platforms and reporting standards.

In addition to USB support, the device allows for direct connection to a printer, streamlining the on-site documentation process. This flexibility in data handling simplifies the process of recording, sharing, and analyzing diagnostic results. 

Specification
Range 20 m - 1280 km at v/2 = 80 m/μs
Pulse Width 20 ns - 10 μs
Pulse Amplitude 30 V - 160 V
Resolution 0.1 m at v/2 80 m/μs, 1 cm at v/2 < 40 m/μs, 20 - 50 m
Accuracy of Distance Measurement ± 0.2% of the measuring range
Sample Rate Up to 400 MHz
Gain –37 dB - + 37 dB
De-attenuation 0 - + 22 dB for ProRange (adjustable 0 - 100 %)
Propagation Velocity v/2 10 - 149.9 m/μs, ft/μs or nvp
Dynamic Range >80 dB
Output Impedance 50 Ω
Compensation 10 Ω - 2 kΩ and ∞, adjustable
ARM-Trigger Automatic adaptation by ΔU trigger or LÎH trigger