  • Voltage range 90 - 600 V, 3 phase, 50/60 Hz with 600 VAC CAT III safety rating
  • Operating and storage temperature range 0 – 40 °C
  • Compact dimensions 5.1 x 3.6 x 1.6 in. (130 x 91 x 41 mm), net weight 14.4 oz (420 g)
  • Includes standard canvas carrying case (7.0 x 3.75 x 4.0 in.) and complies with EN 61010-1 safety standard
Order above 500 AED = Free Delivery
Delivery by * within UAE. When you order in
This item will be delivered by .
Want it Tomorrow?
Select Click & Collect on checkout within the next
We are not Supporting COD Payments Terms Outside UAE
Secure Transaction
This item is eligible for return
Online support
24/7 Support
Original Products
quality guarantee
Fast Delivery
Fastest delivery ever!
Online payment
fast and safe
secure and live track
fast and safe
Description

About this model

Megger PSI700A Phase Sequence Indicator

The Megger PSI700A is a rugged, lightweight instrument designed to determine the phase sequence or phase rotation of a three-phase electrical system. In industrial and commercial applications, knowing the correct phase rotation is critical for the safe operation of rotating machinery, such as motors and generators. Incorrect phase connections can lead to reverse rotation, causing significant equipment damage and operational downtime. The PSI700A addresses these challenges by providing a reliable, immediate visual indication of the system's configuration. Whether you are commissioning a new installation or performing routine maintenance, this device ensures that your three-phase systems are wired correctly and safely.

Beyond simply identifying rotation direction, the Megger PSI700A also serves as a vital diagnostic tool for detecting open phases. An open phase can cause motors to overheat, run inefficiently, or fail to start altogether. By connecting the three leads to the system, technicians can instantly verify the presence of all phase voltages and identify any faults. This capability makes the PSI700A an indispensable tool for electricians, maintenance engineers, and facility managers who prioritize system reliability and safety. When you buy the Megger PSI700A, you are investing in a device that simplifies complex electrical checks into straightforward, actionable results.

Technical Features and Field Applications of the Megger PSI700A

The Megger PSI700A is engineered for ease of use in demanding field environments. Its operational simplicity is a key feature: the operator connects three leads to the system, and the instrument provides immediate visual feedback via lamps. One lamp illuminates to indicate ABC clockwise rotation, while another signals CBA counter-clockwise rotation. This intuitive display eliminates the need for complex interpretations, allowing technicians to make quick, confident decisions on-site. The device's rugged construction ensures it can withstand the rigors of daily use in industrial settings, from manufacturing plants to construction sites.

In addition to phase sequence detection, the PSI700A offers comprehensive system verification. When all three phases are correctly connected and functioning, three lamps will light up, confirming that the full phase system is operational. This feature is particularly valuable during startup procedures or after maintenance, as it provides a quick sanity check before energizing downstream equipment. If a phase is open or missing, the instrument highlights the fault by lighting only one lamp, which helps in rapidly diagnosing issues. For those looking for the best price on a reliable phase indicator, the Megger PSI700A delivers exceptional value through its dual functionality and robust design.

Megger PSI700A Specifications and Operational Limits

Understanding the technical specifications of the Megger PSI700A is essential for maximizing its utility in your specific application. These parameters define the instrument's operational boundaries and ensure safe usage across various electrical environments. The following details outline the voltage range, environmental tolerances, and physical characteristics that make this device suitable for a wide array of three-phase systems.

  • Voltage: For use on 90 to 600 volts, 3ø, 50/60 hertz

The voltage rating is a critical specification that determines where the PSI700A can be safely applied. Covering a range from 90 to 600 volts AC, this instrument is versatile enough for low-voltage control circuits as well as higher-voltage distribution systems. The 50/60 Hz frequency compatibility ensures it works seamlessly with both European and North American electrical standards, making it a global solution for phase verification. This broad compatibility means you can standardize on one tool for multiple sites, simplifying inventory and training.

Input Parameters and Environmental Specifications

To ensure accurate and safe measurements, the input characteristics and environmental operating limits of the Megger PSI700A are clearly defined. These specifications guide users on how to interface the instrument with the electrical system and where it can be reliably used. Adhering to these parameters is crucial for maintaining measurement integrity and the longevity of the device. Below are the key input and environmental details that support its field performance.

  • Voltage: 600VAC CATIII
  • Phase : 3
  • Frequency: 50 / 60 Hz
  • OPERATING TEMPERATURE : 0 – 40 C
  • STORAGE TEMPERATURE : 0 – 40 C
  • DIMENSIONS : 5.1H x 3.6W x 1.6D in.(130H x 91W x 41D mm)

The 600

Specification
General Voltage For use on 90 - 600 V, 3ø, 50/60 Hz
Voltage Level 600 VAC CAT III
Phase and Frequency 3 phase, 50/60 Hz
Temperature Operating Temperature 0 – 40 °C
Storage Temperature 0 – 40 °C
Physical Attributes Dimensions 5.1 H x 3.6 W x 1.6 D in. (130 H x 91 W x 41 D mm)
Net Weight Instrument only 14.4 oz (420 g)
Carrying Case Model PSI700A comes with a standard canvas carrying case
Dimensions 7.0 H x 3.75 W x 4.0 D in. (178 H x 95 W x 102 D mm)
Conformance Standards Safety EN 61010-1 CAT III 600 V
Downloads
FAQs & How To

FAQs

No, the Megger PSI700A Phase Sequence Indicator is powered by the circuit under test, making it ideal for long-term field use.
The unit is designed for use on systems with a nominal voltage between 100V and 700V AC.
Yes, it is designed for live testing and comes with high-quality fused test leads to enhance operator safety.
Yes, the PSI700A is compatible with both 50Hz and 60Hz frequencies, covering standard global power systems.
Reviews (3)
Add a review
/ 5
Related Products
Added to compare list
Added to compare list
Added to compare list
Added to compare list
Added to compare list
Added to compare list
Added to compare list
Added to compare list
NEXT
PREV