Welcome to Uazon! Your one-stop shop for all measuring equipment.

Product Suggestions

Megger
Order Number: 1000-740

Megger PAT320 Portable Appliance Tester

37 views
Delivery
  • Performs Bond, Continuity, Insulation, Leakage, RCD, and Flash Tests up to 3000 V a.c. for Class II devices
  • Operates on 230 V ±10% supply with high accuracy (±2% on Insulation, ±5% on Earth Bond)
  • Features comprehensive RCD testing with trip time accuracy of ±1% ±5 digits
  • Compact and portable design (PAT320: 155 mm x 255 mm x 320 mm, 4.9 kg)
Added to compare list
Order above 500 AED = Free Delivery
Delivery by * within UAE. When you order in
This item will be delivered by .
Want it Tomorrow?
Select Click & Collect on checkout within the next
We are not Supporting COD Payments Terms Outside UAE
Secure Transaction
This item is eligible for return
Online support
24/7 Support
Original Products
quality guarantee
Fast Delivery
Fastest delivery ever!
Online payment
fast and safe
secure and live track
fast and safe
Description

About this model

Megger PAT320 Portable Appliance Tester

Electrical safety testing is a critical responsibility for any facility manager, electrician, or maintenance professional. The Megger PAT320 is a portable appliance tester engineered to meet these demanding requirements with precision and efficiency. Designed to handle a wide array of electrical assets, this instrument provides a comprehensive solution for verifying the safety of portable appliances in various environments.

When you are looking to buy the Megger PAT320, you are investing in a tool that balances high productivity with robust construction and user-friendly operation. The Megger PAT320 price reflects its advanced capabilities, offering exceptional value for professionals who require a complete range of functions for both automatic and manual testing. Whether you are new to PAT testing or an experienced technician seeking to avoid the complexities of built-in database management, the Megger PAT320 is an excellent choice for streamlined, reliable safety verification.

Technical Features and Field Applications of the Megger PAT320

Understanding the practical application of the Megger PAT320’s features is essential for maximizing safety and efficiency in the field. The instrument is engineered to perform a variety of tests with dedicated buttons for direct access, ensuring that workflows are fast and intuitive. Below, we explore the key technical features and how they translate into real-world benefits for electrical safety testing.

  • Simple Manual or Automatic Testing: The PAT320 offers versatile operational modes that adapt to different testing scenarios. In automatic mode, the tester sequences through tests rapidly, increasing productivity for high-volume environments like rental fleets or office buildings. In manual mode, technicians have full control to focus on specific assets or troubleshoot issues, making the Megger PAT320 ideal for detailed inspections and complex repair verification.
  • Multi-Voltage Operation (230 V and 110 V): The ability to operate on both 230 V and 110 V supplies ensures the Megger PAT320 can be used globally, regardless of the local power infrastructure. This flexibility is crucial for multinational companies or professionals working across different sites, allowing for consistent testing standards without needing multiple devices.
  • Comprehensive Bond Testing: With bond testing capabilities at 25 A, 10 A, and 200 mA, the PAT320 provides thorough earth bond verification. The 25 A and 10 A tests are essential for checking the integrity of protective conductors in heavy-duty appliances, while the 200 mA test is perfect for detecting high-resistance connections that could indicate corrosion or loose terminals, ensuring a low-impedance path to earth.
  • Full Colour Display: The vibrant full-colour display enhances readability in various lighting conditions, from dimly lit server rooms to bright industrial floors. Clear visibility of test results, pass/fail indicators, and on-screen prompts reduces the risk of human error and speeds up the interpretation of complex data.
  • Portable RCD and Extension Lead Testing: The PAT320 is capable of testing portable RCDs (Residual Current Devices) and extension leads, two critical components in electrical safety. Verifying the trip times and functionality of RCDs ensures they will operate correctly during a fault, while testing extension leads prevents hazards caused by damaged cables or incorrect wiring.
  • Advanced Leakage Testing: The instrument performs differential, touch, and substitute leakage current tests. These measurements are vital for identifying potential shock risks and insulation breakdowns. By accurately quantifying leakage, technicians can assess the true safety condition of an appliance beyond basic insulation resistance.
  • Pre-set Test Sequences: To streamline compliance with safety standards, the PAT320 includes pre-set test sequences for Class I, Class II, and extension leads. These automated sequences ensure that all necessary measurements are performed in the correct order, minimizing setup time and ensuring consistent, repeatable results across different testers.
  • Flash Testing at 1.5 kV and 3 kV: For high-power insulation verification, the PAT320 supports flash testing at 1.5 kV for Class I appliances and 3 kV for Class II appliances. This high-voltage test stresses the insulation to detect weaknesses that could lead to catastrophic failures, providing an additional layer of safety for critical equipment.
  • Compliance with DIN VDE 0701-0702: The PAT320 is designed to perform tests to DIN VDE 0701-0702 standards, which are widely recognized in European electrical safety protocols. 
Specification
Feature Specification
Electrical Supply Range 230 V ±10% ±1 V at 50 Hz ±10% ±0.1 Hz
Instrument Accuracy Accuracy not guaranteed outside specified supply frequencies
Bond Test (10 A and 25 A) Open circuit voltage: 9 V a.c. ±10% ±0.1 V (Supply: 230 V 50 Hz)
Earth bond resistance accuracy: ±5% ±3 digits (0 - 0.49 Ω), ±5% ±5 digits (0.5 - 1.99 Ω)
Resolution: 10 mΩ (0 - 1.99 Ω)
Display range: 10 - 1.99 Ω
Continuity Test voltage: 4.0 V d.c. -0% +10
Resistance accuracy: ±5% ±3 digits (0 - 0.49 Ω), ±5% ±5 digits (0.5 - 19.99 Ω)
Resolution: 10 mΩ (1 - 19.99 Ω)
Display range: 0 - 19.99 Ω
Insulation Test (250 V & 500 V) Accuracy (230 V): ±2% ±5 digits (0 - 19.99 MΩ), ±5% ±10 digits (20 - 99.99 MΩ)
Resolution: 0.01 MΩ
Display range: 0 - 99.99 MΩ
Substitute Leakage Current Test voltage and frequency: 40 V a.c. ±10% at nominal mains frequency
Accuracy: ±5% ±5 digits
Resolution: 0.01 mA
Display range: 0 - 19.99 mA
Leakage Current Test voltage: Nominal mains supply
Accuracy: ±5% ± 5 digits
Resolution: 0.01 mA
Display range: 0 - 19.99 mA
Touch Current Test Test voltage: Nominal main supply
Accuracy: ±5% ±5 digits
Resolution: 0.01 mA
Display range: 0.00 - 10 mA
Operational Test Test voltage: Nominal mains supply
VA Accuracy: ±5% ±10 digits (0 - 99 VA), ±5% ±50 digits (100 - 999 VA), ±5% ±100 digits (1000 - 3700 VA)
Resolution: 1 VA
Display range: 0 - 3.99 KVA
Ext Lead Test Test performed: Bond insulation and polarity
Polarity test voltage: 12 V d.c.
Polarity outcomes: Lead OK, Live neutral S/C, Live neutral reversed, Live/neutral O/C
Flash Test (PAT350) Voltage: 1500 V a.c nominal for Class I, 3000 V a.c nominal for Class II
Current: < 3.5 mA short circuit at 253 V primary supply voltage
Accuracy: ±5% ±5 digits
Resolution: 0.01 mA
Display range: 0 - 3.0 mA
RCD Tests Voltage and frequency: Nominal mains supply
Current accuracy: -8% - -2% (1/2 x I), +2% - +8% (1 x I, 5 x I)
Trip time accuracy: ±1% ±5 digits
Resolution: 0.1 ms
Display ranges: Various
Fuse Test Voltage: 3.3 V
Indicator: Audible beep if fuse is OK
Temperature and Humidity Operating: -10 - +50 °C, 90% RH at -10 - +30 °C, 75% RH at +30 - +50 °C
Storage: -20 - +60° C, 90% RH at -10 - +30 °C, 75% RH at +30 - +50 °C
Weight PAT310: 3.2 kg, PAT320: 4.9 kg, PAT350: 5.5 kg
Dimensions PAT320: 155 mm (H) x 255 mm (W) x 320 mm (L)
Downloads
FAQs & How To

FAQs

It is used for portable appliance safety testing and routine electrical inspection procedures.
Maintenance personnel, contractors, inspectors, and engineering professionals commonly use this tester.
You can buy the Megger PAT320 Portable Appliance Tester on uazon.ae from an authorized distribiutor.
Portable appliance testing helps improve workplace electrical safety and supports compliance inspection programs.
Yes, it is suitable for maintenance service tasks, engineering projects, and routine compliance inspections.
Contact us through the store; we reply within one business day.

How To

Basic process for performing portable appliance safety testing using the Megger PAT320 Portable Appliance Tester.

Estimated Time: PT10M

Disconnect the appliance from power, visually inspect the equipment, and review safety requirements before testing.
Attach the Megger PAT320 Portable Appliance Tester using the appropriate test lead or appliance connection.
Choose the required appliance safety test routine based on the equipment type and inspection process.
Start the testing process and allow the tester to complete the electrical safety verification sequence.
Check the displayed test outcome and record the results for maintenance, service, or compliance documentation.
Reviews (4)
Add a review
/ 5
Related Products
Added to compare list
Added to compare list
Added to compare list
Added to compare list
Added to compare list
Added to compare list
Added to compare list
Added to compare list