Megger PAT150 Handheld Portable Appliance Testers

30 views
Delivery
  • Operating Temperature: 0 °C - +40 °C with 90% RH humidity tolerance
  • IP40 rating provides basic protection when the front cover is closed
  • Battery operated via eight AA LR6 cells (12 V alkaline or 9.6 V NiMH)
  • Compact dimensions: 203 mm x 148 mm x 78 mm (1150 g instrument weight)
Added to compare list
Order above 500 AED = Free Delivery
Delivery by * within UAE. When you order in
This item will be delivered by .
Want it Tomorrow?
Select Click & Collect on checkout within the next
We are not Supporting COD Payments Terms Outside UAE
Secure Transaction
This item is eligible for return
Online support
24/7 Support
Original Products
quality guarantee
Fast Delivery
Fastest delivery ever!
Online payment
fast and safe
secure and live track
fast and safe
Description

About this model

Buy Megger PAT150: Rugged Handheld Portable Appliance Testers

The Megger PAT150 series represents the pinnacle of handheld portable appliance testing, engineered specifically for electrical safety verification of appliances and equipment in demanding environments. Designed for professionals who require mobility without sacrificing accuracy, the Megger PAT150 combines durability with advanced testing capabilities to ensure compliance with stringent safety standards. When you buy the Megger PAT150, you are investing in a tool that streamlines the safety inspection process, making it ideal for facility managers, electricians, and safety engineers.

Unlike bulkier bench-mounted units, the Megger PAT150 offers the freedom to test equipment in situ, whether in a bustling office, a retail shop, or a challenging industrial warehouse. This device is built to withstand the rigors of daily use, featuring a robust design that prioritizes user safety and operational efficiency. For those seeking the best price on reliable testing equipment, the Megger PAT150 delivers exceptional value by combining portability with comprehensive test coverage.

Technical Features and Field Applications of the Megger PAT150

Understanding the technical features of the Megger PAT150 is essential for maximizing its potential in field applications. This tester is engineered with a rubber-armored case and a scratch-resistant hardened glass display, ensuring it remains operational even in rough conditions. The device is battery-powered, which is a critical feature for testing in locations where a convenient or safe electrical supply is unavailable, such as construction sites or remote warehouses. Below are the key technical features that define the Megger PAT150's performance.

  • Simple ‘tick/cross’ or ‘pass/fail’ indication plus measurement for intuitive operation.
  • Tough, rubber-armored construction with a built-in front cover and hardened, scratch-proof display window.
  • Includes 250 V insulation and leakage testing, ensuring safe testing for IT equipment and surge-protected devices.
  • Capable of testing both portable and fixed electrical equipment with precision.
  • Features 10 mA and 30 mA portable RCD lead testing specifically for the PAT150 model.
  • Offers adjustable PASS test limits (PAT150), allowing for customized safety thresholds.
  • Supports substitute and mains-powered leakage testing (PAT150) for comprehensive analysis.
  • Battery-powered operation with rechargeable options available for extended field use.

General Specifications and Environmental Durability

The Megger PAT150 is designed to operate reliably across a wide range of environmental conditions, making it a versatile tool for global applications. Its specifications reflect a build quality that meets the demands of both indoor and outdoor testing scenarios. When considering the Megger PAT150 price, it is important to factor in the device's resilience to temperature, humidity, and altitude variations, which ensures consistent performance regardless of the work environment.

  • Operating Temperature: 0 °C to +40 °C (32 °F to 104 °F) ensures functionality in standard indoor and outdoor conditions.
  • Storage Temperature: -20 °C to +60 °C (4 °F to 140 °F) allows for safe storage in extreme climates.
  • Humidity: Tolerates 90% RH at 10 °C to 30 °C and 75% RH at 30 °C to 60 °C, preventing moisture-related failures.
  • Operating Altitude: Safe operation up to 2,000 meters, suitable for high-elevation testing sites.
  • IP Rating: IP40 protection (with front cover closed) guards against solid objects larger than 1mm.
  • Battery Type: Powered by eight AA LR6 cells, offering 12 V dc (Alkaline) or 9.6 V dc (NiMH) options for flexible power management.
  • Weight and Dimensions: The instrument weighs approximately 1300g, with compact dimensions of 203 mm L x 148 mm W x 78 mm H, making it highly portable.

Comprehensive Test Capabilities and Performance Metrics

The Megger PAT150 excels in providing a full spectrum of electrical safety tests, from basic continuity to complex leakage current analysis. Each test

Specification

General Specifications

FEATURE SPECIFICATION
Operating Temperature 0 °C to +40 °C (32 °F to 104 °F)
Storage Temperature -20 °C to +60 °C (4 °F to 140 °F)
Humidity 90% RH @ +10 °C to +30 °C, 75% RH @ +30 °C to +60 °C
Operating Altitude Up to 2,000m
IP Rating IP40 (with front cover closed)
Battery Type Eight AA LR6 cells, 12 V dc (Alkaline), 9.6 V dc (NiMH)
Weight (PAT120) 1150g (instrument), 2370g (shipping)
Weight (PAT150) 1300g (instrument), 2975g (shipping)
Dimensions (Instrument and Case) 203 mm L x 148 mm W x 78 mm H (8 x 5.7 x 3.2 inches)
Dimensions (Instrument and Packaging) 456 mm L x 178 mm W x 89 mm H (18 x 7.1 x 3.5 inches)

Test Capabilities and Specifications

TEST SPECIFICATIONS
Continuity Test Voltage: +4 V dc -0% / +30%, Current: +200 mA -0 % + 50 mA, Accuracy: ± 5% ± 3 digits, Resolution: 10 mΩ, Display Range: 0.01 to 19.99 Ω
Insulation Test Voltage: 250 V dc and 500 V dc -0% +25%, Accuracy: ± 3% ± 10 digits, Display Range: 0.10 MΩ to 99.99 MΩ
Substitute Leakage Test Voltage: < 50V ac, Frequency: 50 Hz, Accuracy: ± 5% ± 3 digits, Resolution: 0.01 mA, Display Range: 0.10 to 19.99 mA
Differential Leakage Current Voltage: 230 V ac, Frequency: 50 Hz, Accuracy: ± 5% ± 3 digits ± 3 uA/A, Display Range: 0.10 to 19.99 mA
Touch Current Test Voltage: 230 V ac, Frequency: 50 Hz, Accuracy: ± 5% ± 3 digits, Display Range: 0.10 to 3.99 mA
SELV Device Test Voltage: 0 to 300 V ac, Accuracy: ± 3% ± 3 digits, Display Range: 0.1 to 300 V ac
Extension Lead Test Voltage: 5 V, Conditions: Polarity Lead OK, Live/neutral shorted, reversed, open circuit
Portable RCD Test Voltage: 230 V, Frequency: 50 Hz, Current Accuracy: +2 % to +8 %, Trip Time Accuracy: ± 1 % ± 1 ms, Display Range: 0 to 200 ms (1 x I), 0 to 40 ms (5 x I)
Main Supply Test Frequency: 50 Hz, Voltage: 40 to 300 V ac, Accuracy: ± 3% ± 3 digits, Display Range: 40 to 300 V ac
Safety and Compliance Designed to IEC 61010-1: 2012, Test leads to IEC 61010-031: 2005, Mains fuse protection to 250 V rms ac, EMC compliant with IEC 61326-1: 2012, IEC 61326-2-2: 2012
Downloads
FAQs & How To

FAQs

They are used for portable appliance safety testing and routine electrical inspection procedures.
Maintenance teams, inspectors, contractors, and engineering professionals commonly use them.
You can buy them on uazon.ae from an authorized distribiutor with retail hybrid purchasing support.
They improve mobility, simplify on-site testing, and support efficient appliance safety inspection workflows.
Yes, they are suitable for maintenance service tasks, electrical project work, and routine compliance inspections.
Contact us through the store; we reply within one business day.

How To

Simple process for performing portable appliance safety checks using the Megger PAT150 handheld tester.

Estimated Time: PT10M

Ensure the appliance is unplugged, visually inspect the device and cables, and review safety procedures before testing.
Attach the Megger PAT150 Handheld Portable Appliance Tester to the appliance using the appropriate test lead or connection method.
Choose the required portable appliance test routine based on the type of equipment being inspected.
Start the test using the handheld tester and allow the device to complete the safety verification procedure.
Check the displayed test results and record the outcome for maintenance, service, or compliance documentation.
Reviews (5)
Add a review
/ 5
Related Products
Added to compare list
Added to compare list
Added to compare list
Added to compare list
Added to compare list
Added to compare list
Added to compare list
Added to compare list
NEXT
PREV