Welcome to Uazon! Your one-stop shop for all measuring equipment.

Product Suggestions

Megger
Order Number: LRCD200-EN-BS

Megger LRCD200 Combined Loop and RCD Testers

195 views
Delivery
  • Professional Megger LRCD200 Combined Loop and RCD Testers for electrical safety verification
  • Designed for loop impedance and RCD testing in commercial and industrial installations
  • Reliable measurement performance from the trusted Megger electrical testing brand

Repair request

Megger LRCD200 Combined Loop and RCD Testers · Megger

Step 1 — Instrument details

Step 2 — Contact & return address

Return shipping address

Step 3 — Comments & confirm


Serial number:
What is wrong:
· ·

Request a Rental Quote

Megger LRCD200 Combined Loop and RCD Testers

Step 1 — Rental Details

Step 2 — Contact Information

Step 3 — Confirm

Megger LRCD200 Combined Loop and RCD Testers
Quantity:  ·  Term:
Start date: –
·

Certificate request

Megger LRCD200 Combined Loop and RCD Testers · Megger

Step 1 — Device

First tell us if you already have this product, or want the certificate included with a purchase.

Step 2 — Certificates

Select one or more certificates. Prices shown are optional list prices when the admin set them; otherwise we quote after review.

Step 3 — Your details

Contact

Shipping / return address

Selected Documents Action
Added to compare list
Order above 1000 AED = Free Delivery
Delivery by * within UAE. When you order in
This item will be delivered by .
Want it Tomorrow?
Select Click & Collect on checkout within the next
Secure Transaction
This item is eligible for return (for Warranty only)
Online support
24/7 Support
Original Products
quality guarantee
Fast Delivery
Fastest delivery ever!
Online payment
fast and safe
secure and live track
fast and safe
Description

About this model

Technical Features and Field Applications of the Megger LRCD200

The Megger LRCD200 is a robust and reliable RCD loop tester designed to meet the rigorous demands of modern electrical maintenance. For electricians and technicians, the ability to verify loop impedance and test residual current devices quickly and safely is not just a convenience but a necessity for compliance and hazard prevention. This instrument combines Megger’s renowned accuracy with a compact form factor, making it an essential tool for both residential inspections and commercial installations. By focusing on high-performance metrics and user safety, the Megger LRCD200 ensures that field professionals can conduct critical tests without compromising on speed or reliability.

When considering the purchase of high-quality testing equipment, the Buy Megger LRCD200 option represents an investment in long-term operational efficiency. Unlike generic multimeters, this specialized loop tester offers targeted functionality for RCD verification, ensuring that every measurement adheres to strict international safety standards. For those evaluating the Megger LRCD200 Price, the value lies in its durability and the reduction of downtime during complex electrical assessments. This article explores the technical specifications, operational benefits, and practical applications that make this device a top choice for industry professionals.

Comprehensive Testing Capabilities and Safety Standards

The core strength of the Megger LRCD200 lies in its ability to perform comprehensive testing in accordance with EN 61557 standards. This compliance ensures that every loop impedance measurement and RCD test meets rigorous accuracy and safety criteria. By adhering to these standards, the device provides reliable data that technicians can trust when making critical safety decisions. The instrument is engineered to deliver precise pass/fail indicators, eliminating guesswork and ensuring that installations are safe for operation.

Equipped with a no-trip loop test feature, the Megger LRCD200 allows for safe measurements on circuits equipped with RCDs without causing nuisance tripping. This is particularly valuable in live environments where accidental power interruptions can disrupt operations or pose safety risks. The device operates effectively within a wide voltage range of 200 V to 280 V at 45–65 Hz, making it versatile for various electrical systems. When you Buy Megger LRCD200, you are acquiring a tool that prioritizes operator safety through IEC61010 Cat III 300 V compliance, offering robust protection during high-energy fault scenarios.

Portability and Durability for Field Use

Field conditions often present challenges that can compromise delicate electronics, but the Megger LRCD200 is built to withstand them. Weighing under 1 kg, this portable and lightweight device is designed for easy transport to job sites without sacrificing performance. Its compact form factor allows it to fit comfortably in a technician’s toolkit, ensuring that critical testing equipment is always within reach. The ergonomic design reduces user fatigue during prolonged testing sessions, enhancing overall productivity.

Durability is further reinforced by IP54 environmental protection, which shields the unit from dust ingress and water splashes. This rugged construction makes the Megger LRCD200 suitable for harsh field conditions, from dusty construction sites to damp commercial basements. The long battery life—capable of supporting up to 2000 tests on a single set of AA batteries—minimizes the need for frequent battery changes, reducing operational interruptions. For those comparing the Megger LRCD200 Price, this level of resilience and battery efficiency contributes to a lower total cost of ownership over time.

Technical Features and Field Applications

Understanding the technical features of the Megger LRCD200 reveals how it streamlines routine electrical inspections. The device provides precise loop resistance readings, which are essential for verifying fault protection paths and ensuring that circuits can safely handle fault currents. Clear pass/fail indicators simplify interpretation, allowing technicians to make quick decisions without extensive data analysis. This feature is particularly useful during high-volume inspections where speed and accuracy are equally important.

Applications for the Megger LRCD200 span a wide range of electrical environments. In domestic settings, it verifies RCDs in residential wiring to protect against electric shock hazards. In commercial and light industrial installations, it conducts loop impedance measurements to confirm compliance with safety standards during routine maintenance. The device is also ideal for field use where portability and accuracy are essential, such as in facility management or emergency repair scenarios. By integrating this tool into daily workflows, technicians can ensure consistent adherence to international safety protocols.

Specification
Category Parameter Specification
Voltage Measurement (LRCD200, 210, 220) Range 0 V – 500 V
Accuracy ±2% ±2 digits
Frequency Measurement (LRCD200, 210, 220) Range 25 Hz – 450 Hz
Accuracy 25.0 Hz – 199.9 Hz: ±0.1 Hz
  200 Hz – 450 Hz: ±1 Hz
Phase Rotation Indicator (LRCD220 only) Identification Three wire phase rotation
Frequency 45 Hz – 65 Hz
Loop Testing (EN 61557-3) Supply (LRCD200/210) 200 V – 280 V, 45–65 Hz
Supply (LRCD220) 100 V – 280 V, 45–65 Hz
Nominal Test Current 15 mA
Loop Accuracy 0.01 Ω – 9.99 Ω: ±5% ±0.03 Ω
  10.0 Ω – 99.9 Ω: ±5% ±0.5 Ω
  100 Ω – 999 Ω: ±5% ±5 Ω
  1.00 kΩ – 2.00 kΩ: ±5% ±30 Ω
HI Current Line/Earth Loop Test 2-wire (LRCD220 only) Supply: 100 V – 480 V | Nominal Test Current: 15 mA – 2.4 A
Loop Accuracy 0.01 Ω – 9.99 Ω: ±5% ±0.03 Ω
Line/Line (LRCD220 only) Supply: 100 V – 480 V, 45–65 Hz
Prospective Fault Current (PSCC) Formula Nominal supply voltage ÷ Loop resistance
Accuracy Derived from loop test
Ranges 1 A – 199 A (1 A resolution)
  0.20 kA – 1.99 kA (10 A resolution), 2.0 kA – 19.9 kA (100 A resolution)
RCD Testing (EN61557-6) LRCD200/210 10, 30, 100, 300, 500 mA
LRCD220 10, 30, 100, 300, 500, 1000 mA
Supply (LRCD200/210) 200 V – 280 V, 45–65 Hz
Supply (LRCD220) 100 V – 280 V, 45–65 Hz
Test Current Accuracy No Trip (½I): -8% to -2% | Trip (I, 5I): +2% to +8% | Trip Time: ±1% ±1 ms
Fault (Touch) Voltage Displayed Range 0 V – 50 V
Error +5% / +15% ±0.5 V
Environmental Conditions Operating Range -5 °C – +40 °C
Operating Humidity 93% RH at +40 °C max
Storage Range -25 °C – +70 °C
Altitude 2000 m max
Protection IP54
Safety IEC61010 Cat III 300 V phase to earth
EN61557 Compliance Part 1 – General Requirements
Part 3 – Loop Resistance
Part 6 – Residual Current Devices
Power Supply Battery 8 × 1.5 V cells (IEC LR6 AA alkaline)
Rechargeable 8 × 1.2 V NiCd or NiMH cells
Battery Life 2000 consecutive tests
Physical Weight 980 g
Dimensions 203 × 148 × 78 mm
Electromagnetic Compatibility Standard IEC61326
Downloads
FAQs & How To

FAQs

It is used to measure loop impedance and test residual current devices to verify electrical safety and protection systems.
Electrical engineers, inspectors, maintenance technicians, and contractors use it for testing electrical installations.
They can be purchased from authorized electrical equipment suppliers such as uazon.ae.
Yes, it is commonly used in electrical commissioning, project inspections, and maintenance testing.
These tests confirm that electrical protection systems operate correctly to reduce the risk of electric shock and faults.

How To

Step-by-step guide to safely perform loop impedance and RCD testing using the Megger LRCD200 electrical installation tester.

Estimated Time: PT15M

Install the correct batteries, inspect the tester and leads for damage, and ensure the circuit under test is energized and safe to measure according to electrical safety procedures.
Connect the tester leads to the circuit outlet or terminals: line (L), neutral (N), and earth (E). Ensure connections are firm and that the tester indicates correct wiring before proceeding.
Turn the function selector to the required test mode. Choose loop impedance testing for circuit impedance verification or select the RCD test function for residual current device testing.
Press the test button to start the measurement. The tester injects a controlled test current to measure loop impedance or initiates the RCD test sequence to check trip operation.
Read the measured value on the display such as loop impedance, prospective fault current, or RCD trip time. Record the results for compliance documentation and inspection reports.
Reviews (13)
Add a review
/ 5
Related Products
Added to compare list
Added to compare list
Added to compare list
Added to compare list
Added to compare list
Added to compare list
Added to compare list
Added to compare list
NEXT
PREV