Welcome to Uazon! Your one-stop shop for all measuring equipment.

Product Suggestions

Megger
Order Number: 1015-515

Megger AVO850 Advanced True-RMS Multimeter

151 views
In stock
Delivery
  • High-precision multimeter with 1000 V AC/DC voltage and 10 A current measurement ranges
  • Excellent accuracy: ±0.05% for DC voltage and ±0.2% for resistance
  • Features Temperature (Type-K), Capacitance, Frequency, and Duty Cycle measurements
  • Includes Relative mode (REL) for offset compensation and True RMS capability
Added to compare list
Price history of Megger AVO850 Advanced... Recent changes to this price
Lowest: AED 1,750.00 Highest: AED 1,850.00 Current: AED 1,850.00
AED 1,850.00 AED 1,800.00 AED 1,750.00 Date
Apr 14 May 18
2 changes tracked
Order above 1000 AED = Free Delivery
Delivery by * within UAE. When you order in
This item will be delivered by .
Want it Tomorrow?
Select Click & Collect on checkout within the next
We are not Supporting COD Payments Terms Outside UAE
Secure Transaction
This item is eligible for return (for Warranty only)
Online support
24/7 Support
Original Products
quality guarantee
Fast Delivery
Fastest delivery ever!
Online payment
fast and safe
secure and live track
fast and safe
Description

About this model

Buy Megger AVO850: Professional True-RMS Digital Multimeter with Bluetooth

The Megger AVO850 True-RMS Digital Multimeter is a premium-grade instrument engineered for electricians, field engineers, and industrial maintenance teams who demand absolute accuracy and rugged durability. Built with Megger's trusted reliability, this industrial multimeter is the ideal solution for HVAC system testing, power distribution diagnostics, renewable energy verification, and complex troubleshooting. When you are looking for the best price on a professional tool that combines traditional robustness with modern connectivity, the AVO850 stands out as a top contender in the market. It offers the precision required to diagnose modern electrical systems safely, ensuring that every measurement is reliable under the harshest site conditions.

True-RMS Measurement Technology and Performance

Unlike basic testers that struggle with distorted signals, the AVO850 utilizes advanced True-RMS measurement to provide accurate AC readings on distorted or non-linear waveforms. This capability is essential for modern industrial environments where Variable Frequency Drives (VFDs), motor controllers, and harmonics-heavy circuits are standard. By averaging the value of a waveform, standard meters often provide incorrect readings on these complex loads; however, the AVO850 captures the true root mean square value, ensuring data integrity. With impressive ranges up to 1000 V AC/DC and 10 A current, this meter delivers consistent results even in the most challenging electrical environments, making it a vital asset for any high-energy system analysis.

Technical Features and Field Applications of the Megger AVO850

Engineered for versatility, the Megger AVO850 consolidates multiple specialized tools into a single, efficient device, streamlining your workflow and reducing the need to carry various instruments. It is designed to handle a wide array of tasks, from basic continuity checks to advanced diagnostics. The device features a bright, easy-to-read display and intuitive controls that allow for rapid testing without compromising safety. The following core capabilities highlight why this meter is essential for professional technicians:

  • Comprehensive measurement capabilities including AC/DC voltage, current, resistance, continuity, capacitance, frequency, duty cycle, diode testing, and temperature using the included Type-K thermocouple.
  • A high-resolution 6000-count backlit LCD with an analogue bar graph allows for clear visualization of fluctuating signals and rapid data interpretation in low-light conditions.
  • Advanced capture functions such as Min/Max/Avg, Peak Hold, Relative mode, and Data Hold, which are critical for documenting intermittent faults and tracking voltage spikes.
  • Auto-ranging with manual override ensures faster testing by automatically selecting the correct range, while still allowing the user to lock settings for repetitive measurements.

Safety Certifications and Rugged Design Standards

Safety is non-negotiable in professional environments, and the Megger AVO850 is built to meet the highest industry standards. It is certified to CAT IV 600 V / CAT III 1000 V and is fully compliant with IEC 61010-1 safety regulations. This high safety rating makes it suitable for use at the source of the installation, such as main incoming supplies and distribution panels. Additionally, the meter features a double-moulded, impact-resistant housing that provides extra protection against accidental drops and harsh site conditions. Its ergonomic, compact design ensures comfortable handling during extended use, allowing you to work longer without fatigue while maintaining complete confidence in your equipment's integrity.

Bluetooth Data Logging and Connectivity

In today's data-driven industry, the ability to record and analyze measurements remotely is a significant efficiency booster. The Megger AVO850 features integrated Bluetooth connectivity, allowing you to send real-time measurement data directly to a smartphone or tablet. This functionality enables remote monitoring, making it safer and easier to take readings from hazardous or hard-to-reach areas without compromising your position. By utilizing the dedicated mobile application, users can log data, generate reports on the go, and share results instantly with colleagues or clients, streamlining the documentation process and enhancing overall job site productivity.

Why the Megger AVO850 is the Best Price-to-Performance Choice

When you choose the Megger AVO850, you are investing in a legacy of professional-grade instrumentation. It is the perfect upgrade from entry-level or mid-range multimeters for engineers seeking long-term durability and modern features. This device combines industrial reliability with the modern usability required by today's technicians. It is specifically designed for preventive maintenance, commissioning, and troubleshooting tasks where failure is not an option. If you are looking to buy a digital multimeter that offers the best price in

Specification
Function Range Resolution Accuracy / Conditions
AC Voltage
AC Voltage 500 mV 0.01 mV (±0.5% + 5) at 50/60 Hz
AC Voltage 5 V 0.0001 V (±1.0% + 5) at 50/60 Hz; (±3.0% + 5) <1 kHz; (±5.5% + 20) <5 kHz
AC Voltage 50 V 0.001 V (±1.5% + 10) at 50/60 Hz; (±3.5% + 10) <1 kHz; unspecified <5 kHz
AC Voltage 500 V 0.01 V (±1.5% + 10) at 50/60 Hz; (±3.5% + 10) <1 kHz; unspecified <5 kHz
AC Voltage 1000 V 0.1 V unspecified at 50/60 Hz and <1 kHz
* For ACV: upper 10% of range applies for &lt;20 kHz band.
DC Voltage
DC Voltage 500 mV * 0.01 mV (±0.1% + 5 digits)
DC Voltage 5 V 0.0001 V (±0.05% + 5 digits)
DC Voltage 50 V 0.001 V (±0.05% + 5 digits)
DC Voltage 500 V 0.01 V (±0.05% + 5 digits)
DC Voltage 1000 V 0.1 V (±0.1% + 5 digits)
* Use REL mode (REL Q) to compensate for offsets.
AC + DC Voltage
AC+DC 5 V 0.0001 V (±1.2% + 20) <1 kHz; (±3.0% + 20) <5 kHz
AC+DC 50 V 0.001 V
AC+DC 500 V 0.01 V
AC+DC 1000 V 0.1 V
Resistance
Resistance 500 Ω * 0.01 Ω (±0.20% + 10)
Resistance 5 kΩ 0.0001 kΩ (±0.20% + 5)
Resistance 50 kΩ 0.001 kΩ (±0.20% + 5)
Resistance 500 kΩ 0.01 kΩ (±0.50% + 5)
Resistance 5 MΩ 0.0001 MΩ (±0.50% + 5)
Resistance 50 MΩ 0.001 MΩ (±2.0% + 10)
* Use REL mode (REL Q) to compensate for offsets.
Temperature (Type-K)
Temperature (Type-K) −200 - 1350 °C 0.1 °C (±1.0% of reading + 3.0 °C) / (±1.0% of reading + 5.4 °F). Probe accuracy not included.
DC Current
DC Current 500 µA 0.01 µA (±0.2% + 5)
DC Current 5000 µA 0.1 µA (±0.2% + 5)
DC Current 50 mA 0.001 mA (±0.2% + 5)
DC Current 500 mA 0.01 mA (±0.3% + 8)
DC Current 10 A 0.001 A (±0.5% + 8)
AC Current
AC Current 500 µA 0.01 µA (±0.8% + 5) <1 kHz; (±3% + 5) <5 kHz
AC Current 5000 µA 0.1 µA
AC Current 50 mA 0.001 mA
AC Current 500 mA 0.01 mA
AC Current 10 A 0.001 A
All AC current ranges specified from 5% to 100% of range. Burden: mA input ≈ 3.8 mV/A, A input ≈ 30 mV/A.
Capacitance
Capacitance 5 nF * 0.001 nF (±1.5% + 20)
Capacitance 50 nF 0.01 nF (±1.5% + 8)
Capacitance 500 nF 0.1 nF (±1.0% + 8)
Capacitance 5 µF 0.001 µF (±1.5% + 8)
Capacitance 50 µF 0.01 µF (±1.0% + 8)
Capacitance 500 µF 0.1 µF (±1.5% + 8)
Capacitance 10 mF 0.01 mF (±2.5% + 20)
* With film capacitor or better; use REL to zero residual.
Electronic Frequency
Electronic Frequency 50 Hz 0.001 Hz (±0.05% + 5)
Electronic Frequency 500 Hz 0.01 Hz (±0.01% + 5)
Electronic Frequency 5 kHz 0.0001 kHz (±0.01% + 5)
Electronic Frequency 50 kHz 0.001 kHz (±0.01% + 5)
Electronic Frequency 500 kHz 0.01 kHz (±0.01% + 5)
Electronic Frequency 5 MHz 0.0001 MHz (±0.01% + 5)
Electronic Frequency 10 MHz 0.001 MHz unspecified
Electrical Frequency
Electrical Frequency 10.00 Hz – 10 kHz 0.01 Hz – 0.001 kHz (±0.5% of reading)
Duty Cycle
Duty Cycle 0.1% – 99.90% 0.01% (±1.2% of reading + 2 digits). Pulse width: 100 µs – 100 ms; Frequency: 5 Hz – 150 kHz.
Downloads
Reviews (0)
Add a review
/ 5
Related Products
Added to compare list
Added to compare list
Added to compare list
Added to compare list
Added to compare list
Added to compare list
Added to compare list
Added to compare list
NEXT
PREV