Welcome to Uazon! Your one-stop shop for all measuring equipment.

Product Suggestions

Hioki

Hioki IM3570 Impedance Analyzer

32 views
In stock
Delivery
  • 4 Hz to 5 MHz measurement frequency range
  • 0.5 ms ultra-fast measurement speed
  • ±0.08% basic Z accuracy for precise testing
  • LCR mode, Analyzer mode, and Continuous measurement modes
  • Comprehensive parameter set: Z, Y, Rs, Rp, Rdc, Cs, Cp, Ls, Lp, D, Q and more
  • 40 mV to 5 Vrms / 10 μA to 50 mArms measurement signal levels
  • 5.7-inch color TFT display with memory and comparator functions
Order above 1000 AED = Free Delivery
Delivery by * within UAE. When you order in
This item will be delivered by .
Want it Tomorrow?
Select Click & Collect on checkout within the next
Secure Transaction
This item is eligible for return (for Warranty only)
Online support
24/7 Support
Original Products
quality guarantee
Fast Delivery
Fastest delivery ever!
Online payment
fast and safe
secure and live track
fast and safe
Description

About this model

The Hioki IM3570 Impedance Analyzer delivers comprehensive LCR, DCR, and sweep measurement capabilities in a single, versatile instrument. Designed for engineers and quality control professionals, this analyzer covers a wide frequency range from 4 Hz to 5 MHz with exceptional accuracy of ±0.08% for impedance measurements. The instrument features multiple measurement modes including LCR mode, Analyzer mode for frequency sweeps, and continuous measurement functionality, making it suitable for diverse testing applications from component characterization to production line quality assurance.

  • Quality control engineers in manufacturing environments
  • Research and development technicians
  • Electronics production managers
  • Laboratory technicians and researchers
  • Component testing specialists
  • Product design engineers
  • Quality assurance professionals

Hioki IM3570 Key Features

Highlights drawn from the manufacturer documentation for the Hioki IM3570.

  • [Basic specifications]
  • Measurement modes: LCR mode, Analyzer mode (Sweeps with measurement frequency and measurement level), Continuous measurement mode
  • Measurement parameters: Z, Y, θ, Rs (ESR), Rp, Rdc (DC resistance), X, G, B, Cs, Cp, Ls, Lp, D (tanδ), Q
  • Measurement range: 100 mΩ to 100 MΩ, 12 ranges (All parameters are determined according to Z)
  • Display range: Z, Y, Rs, Rp, Rdc, X, G, B, Ls, Lp, Cs, Cp : ±(0.000000 [unit] to 9.999999G [unit], Absolute value display for Z and Y only θ : ±(0.000° to 180.000°), D : ±(0.000000 to 9.999999) Q : ±(0.00 to 99999.99), Δ % : ±(0.0000% to 999.9999%)
  • Basic accuracy: Z ±0.08% rdg. θ: ±0.05°
  • Measurement frequency: 4 Hz to 5 MHz (5 digits setting resolution, minimum resolution 10 mHz)
  • Measurement signal level: Normal mode: V mode/CV mode: 5 mV to 5 Vrms (up to 1 MHz) 10 mV to 1 Vrms (1.0001 MHz to 5 MHz), 1 mVrms steps CC mode: 10 μA to 50 mArms (up to 1 MHz) 10 μA to 10 mArms (1.0001 MHz to 5 MHz), 10 μArms steps Low impedance high repeatability mode: V mode/CV mode: 5 mV to 1 Vrms (up to 100 kHz), 1 mVrms steps CC mode:10 μA to 100 mArms (100 mΩ and 1Ω ranges of up to 100 kHz), 10 μArms steps

Who Needs the Hioki IM3570?

The Hioki IM3570 is built for professionals who need a reliable, documented instrument before they commit budget or schedule. Use the Specs tab to confirm fit, then request a quote from uazon.ae.

  • Electrical contractors and panel technicians
  • Industrial maintenance and reliability teams
  • Plant engineers and instrumentation buyers
  • Service companies stocking genuine Hioki tools
  • QA / commissioning teams needing clear specification detail

Hioki IM3570 Applications

Typical jobs for the Hioki IM3570 focus on fast verification, safer troubleshooting, and repeatable results in the field or workshop.

  • Commissioning and acceptance checks
  • Preventive maintenance rounds
  • Diagnostic troubleshooting of live systems
  • Documentation for audits and work packs
  • Comparing models before purchase
Specification

Basic specifications

Accuracy guaranteed: 1 year

Measurement parameters Z, Y, θ, Rs (ESR), Rp, Rdc (DC resistance), X, G, B, Cs, Cp, Ls, Lp,
D (tanδ), Q
Measurement range 100 mΩ to 100 MΩ, 12 ranges (All parameters are determined according to Z)
Display range Z, Y, Rs, Rp, Rdc, X, G, B, Ls, Lp, Cs, Cp :
±(0.000000 [unit] to 9.999999G [unit], Absolute value display for Z and Y only
θ : ±(0.000° to 180.000°), D : ±(0.000000 to 9.999999)
Q : ±(0.00 to 99999.99), Δ % : ±(0.0000% to 999.9999%)
Basic accuracy Z ±0.08% rdg. θ: ±0.05°
Measurement frequency 4 Hz to 5 MHz (5 digits setting resolution, minimum resolution 10 mHz)
Measurement signal level Normal mode:
V mode/CV mode: 5 mV to 5 Vrms (up to 1 MHz)
10 mV to 1 Vrms (1.0001 MHz to 5 MHz), 1 mVrms steps
CC mode: 10 μA to 50 mArms (up to 1 MHz)
10 μA to 10 mArms (1.0001 MHz to 5 MHz), 10 μArms steps
Low impedance high repeatability mode:
V mode/CV mode: 5 mV to 1 Vrms (up to 100 kHz), 1 mVrms steps
CC mode:10 μA to 100 mArms (100 mΩ and 1Ω ranges of up to 100 kHz), 10 μArms steps
Output impedance Normal mode: 100 Ω, Low impedance high repeatability mode: 10 Ω
Display 5.7-inch color TFT, display can be set to ON/OFF
Measurement time 0.5 ms (100 kHz, FAST, display OFF, representative value)
Functions DC bias measurement, Comparator, BIN measurement (classification), Panel loading/saving, Memory function
Interfaces EXT I/O (handler), RS-232C, GP-IB, USB communication, USB memory, LAN
Power supply 90 to 264 V AC, 50/60 Hz, 150 VA max.
Dimensions and mass 330 mm (12.99 in) W × 119 mm (4.69 in) H × 307 mm (12.09 in) D, 5.8 kg (204.6 oz)
Included accessories Power cord × 1, Instruction manual × 1