Welcome to Uazon! Your one-stop shop for all measuring equipment.

Product Suggestions

Brand: —

Fluke 1587 FC Insulation Tester Multimeter CN

9 views
In stock
Delivery
  • Professional-grade insulation resistance testing up to 2GΩ

  • High-performance digital multimeter functions

  • Designed for the CN market with reliable build quality

  • Integrated Fluke Connect compatibility for smartphone data logging

Added to compare list
Order above 500 AED = Free Delivery
Delivery by * within UAE. When you order in
This item will be delivered by .
Want it Tomorrow?
Select Click & Collect on checkout within the next
We are not Supporting COD Payments Terms Outside UAE
Secure Transaction
This item is eligible for return
Online support
24/7 Support
Original Products
quality guarantee
Fast Delivery
Fastest delivery ever!
Online payment
fast and safe
secure and live track
fast and safe
Description

About this model

Fluke 1587 FC Insulation Tester Multimeter CN

The Fluke 1587 FC Insulation Tester Multimeter CN is a practical choice for users who want a reliable insulation tester and digital multimeter in one tool. At uazon.ae, this model is positioned for engineering, project work, maintenance, and service tasks where fast electrical troubleshooting matters. This CN version is made in China, so it is distinct from the original variant, and that should be clearly noted for buyers comparing options. If you want to buy Fluke 1587 FC Insulation Tester Multimeter CN or shop Fluke 1587 FC Insulation Tester Multimeter CN online, this page is built to help you choose with confidence.

Fluke 1587 FC Insulation Tester Multimeter CN Short Description

  • Fluke 1587 FC Insulation Tester Multimeter CN for insulation testing and multimeter use
  • Made in China version, clearly different from the original unit
  • Suitable for project, service, and engineering applications
  • Available through uazon.ae as an authorized retail hybrid distribiutor
  • Good choice when checking Fluke 1587 FC Insulation Tester Multimeter CN price

Fluke 1587 FC Insulation Tester Multimeter CN Features

Why buyers choose this CN model

This Fluke 1587 FC Insulation Tester Multimeter CN combines everyday testing convenience with a professional workflow for electrical diagnostics. It is a smart option for teams that need one device for insulation testing, electrical troubleshooting, and routine field work. The CN version is a budget-friendly alternative for users who want the Fluke-style experience while understanding it is the China-made version.

Built for field use

With a design focused on practical testing, this model supports efficient work in environments where accuracy, speed, and simple operation matter. It is well suited for users comparing insulation tester multimeter options and looking for a dependable solution from an authorized uazon.ae source.

Fluke 1587 FC Insulation Tester Multimeter CN Applications

  • Electrical maintenance and troubleshooting
  • Project installation and commissioning work
  • Service visits and site inspections
  • Engineering test and measurement tasks
  • Insulation testing during preventive maintenance
  • General multimeter checks for daily field use
Specification

AC Voltage Measurement

Range Resolution Accuracy (50 Hz to 60 Hz) Accuracy (60 Hz to 5000 Hz)
600.0 mV 0.1 mV ±(1% + 3) ±(2% + 3)
6.000 V 0.001 V ±(1% + 3) ±(2% + 3)
60.00 V 0.01 V ±(1% + 3) ±(2% + 3)
600.0 V 0.1 V ±(1% + 3) ±(2% + 3)
1000 V 1 V ±(2% + 3) ±(2% + 3)

Low-Pass Filter Voltage

Range Resolution Accuracy (50 Hz to 60 Hz) Accuracy (60 Hz to 400 Hz)
600.0 mV 0.1 mV ±(1% + 3) +(2% + 3), -(6% - 3)
6.000 V 0.001 V ±(1% + 3) +(2% + 3), -(6% - 3)
60.00 V 0.01 V ±(1% + 3) +(2% + 3), -(6% - 3)
600.0 V 0.1 V ±(1% + 3) +(2% + 3), -(6% - 3)
1000 V 1 V ±(2% + 3) +(2% + 3), -(6% - 3)

DC Voltage Measurement

Range Resolution Accuracy
600.0 mV (DC Millivolts) 0.1 mV ±(0.01% + 1)
6.000 V 0.001 V ±(0.09% + 2)
60.00 V 0.01 V ±(0.09% + 2)
600.0 V 0.1 V ±(0.09% + 2)
1000 V 1 V ±(0.09% + 2)
  • Input impedance: 10MΩ (nominal), <100pF
  • Normal mode rejection ratio: <60dB @ 50Hz
  • Common mode rejection ratio: <120dB @ 50Hz or 60Hz (1 kΩ unbalance)

Current Measurement

Measurement Type Range Resolution Accuracy Burden Voltage
AC Current (45Hz to 1000Hz) 60 mA 0.01 mA ±(1.5% + 2) 2 mV/mA
400 mA 0.1 mA ±(1.5% + 2)1 2 mV/mA
DC Current 60 mA 0.01 mA ±(0.2% + 2) 2 mV/mA
400 mA 0.1 mA ±(0.2% + 2) 2 mV/mA
  • 1 Accuracies apply from 0% to 100% of range.
  • Overload: 600mA for 2 minutes maximum
  • Fuse protection for mA input: 0.44A (440 mA), 1000V, IR 10kA
  • AC conversion: Inputs are AC-coupled and calibrated to the RMS value of sine wave input (1 kHz bandwidth)

Resistance Measurement

Range Resolution Accuracy
600.0 Ω 0.1 Ω ±(0.9% + 2)
6.000 kΩ 0.001 kΩ ±(0.9% + 2)
60.00 kΩ 0.01 kΩ ±(0.9% + 2)
600.0 kΩ 0.1 kΩ ±(0.9% + 2)
6.000 MΩ 0.001 MΩ ±(0.9% + 2)
50.0 MΩ2 0.01 MΩ ±(1.5% + 3)
  • 2 Up to 80% RH
  • Overload protection: 1000V RMS or DC
  • Open circuit test voltage: <8.0V DC
  • Short circuit current: <1.1mA

Diode & Continuity Tests

Test Parameter Indication / Specifications Accuracy / Test Conditions
Diode Test Displays voltage drop 0.6V at 1mA nominal ±(2% + 3)
Continuity Test Continuous buzzer for <25Ω, off above 100Ω (Max reading: 1000Ω) Open circuit voltage: <8.0V
Short circuit current: 1.0mA typical
Response time: >1ms
Overload protection: 1000V RMS

Frequency Measurement

Range Resolution Accuracy
99.99 Hz 0.01 Hz ±(0.1% + 1)
999.9 Hz 0.1 Hz ±(0.1% + 1)
9.999 kHz 0.001 kHz ±(0.1% + 1)
99.99 kHz 0.01 kHz ±(0.1% + 1)

Frequency Counter Sensitivity

Input Voltage Range V AC Sensitivity (RMS Sine Wave) 5Hz to 100kHz DC Trigger Levels 1Hz to 20kHz
600 mV AC 100 mV / 150 mV N/A
6 V 1 V / 1.5 V -400.0 mV and 2.5 V
60 V 10 V / 36 V 1.2 V and 4.0 V
600 V 100 V 12 V and 40 V
1000 V 300 V 12 V and 40 V

Capacitance & Temperature Measurement

Measurement Type Range Resolution Accuracy
Capacitance 1000 nF 1 nF ±(1.2% + 2)
10.00 µF 0.01 µF ±(1.2% + 2)
100.0 µF 0.1 µF ±(1.2% ± 90 counts)
9999 µF 1 µF ±(1.2% ± 90 counts)
Temperature -40°C to 537°C 0.1°C ±(1% + 10)1
  • 1 Accuracies apply following 90 minutes settling time after a change in the ambient temperature of the instrument.

Insulation Test Specifications

Parameter Specification Details
Measurement Range 0.01MΩ to 2GΩ
Test Voltages 50, 100, 250, 500, 1000V
Test Voltage Accuracy +20%, -0%
Short-Circuit Test Current 1mA nominal
Auto Discharge Discharge time <0.5 second for C = 1µF
Live Circuit Detection Inhibit test if terminal voltage >30V prior to initialisation of test
Maximum Capacitive Load Operable with up to 1µF load

Insulation Output Voltage & Ranges

Test Voltage Display Range Resolution Test Current Accuracy
50V (0% to +20%) 0.01 to 6 MΩ 0.01 MΩ 1mA @ 50kΩ ±(3% + 5)
6 to 50 MΩ 0.1 MΩ
100V (0% to +20%) 0.01 to 6 MΩ 0.01 MΩ 1mA @ 100kΩ ±(3% + 5)
6 to 60 MΩ 0.1 MΩ 1mA @ 100kΩ ±(3% + 5)
60 to 100 MΩ 1 MΩ 1mA @ 250kΩ ±(1.5% + 5)
250V (0% to +20%) 0.1 to 60 MΩ 0.1 MΩ 1mA @ 250kΩ ±(1.5% + 5)
60 to 250 MΩ 1 MΩ
500V (0% to +20%) 0.1 to 60 MΩ 0.1 MΩ 1mA @ 500kΩ ±(1.5% + 5)
60 to 500 MΩ 1 MΩ
1000V (0% to +20%) 0.1 to 60 MΩ 0.1 MΩ 1mA @ 1 MΩ ±(1.5% + 5)
60 to 600 MΩ 1 MΩ
0.6 to 2.0 GΩ 100 MΩ 1mA @ 1 MΩ ±(10% + 3)

General Specifications

Feature Technical Parameters
Maximum Voltage 1000 V
Operating Temperature -20°C to 55°C
Storage Temperature -40°C to 60°C
Temperature Coefficient 0.05 x (specified accuracy) per °C for temperatures <18 °C or >28 °C
Relative Humidity (Non-condensing) 0% to 95% @ 10 °C to 30 °C
0% to 75% @ 30 °C to 40 °C
0% to 40% @ 40 °C to 55 °C
Vibration Random, 2g, 5-500Hz per MIL-PRF-28800F, Class 2
Radio Frequency (RF) Communication: 2.4 GHz ISM Band
Certification: FCC (T68-FBLE), IC (6627A-FBLE)
Safety Standards IEC 61010-1 (Pollution Degree 2)
IEC 61010-2-033: CAT IV 600V / CAT III 1000V
Power Supply & Battery Life Four AA batteries (NEDA 15A or IEC LR6); ~1000 hours runtime
Dimensions (H x W x L) 100 x 100 x 203 mm
Weight 550 g
Altitude 2000m (operating) / 12000m (storage)
Other Protections Over-range capability: 11% of range (except capacitance: 100%)
Frequency overload protection: <107 V Hz
Fuse protection: 0.44A, 1000V, IR 10kA
Downloads
FAQs & How To

FAQs

Yes, this is the CN version and it is made in China.
It is the China-made version, so buyers should compare it separately from the original unit.
It suits project, service, maintenance, and engineering users who need a combined insulation tester and multimeter.
Reviews (0)
Add a review
/ 5
Related Products
Added to compare list
Added to compare list
Added to compare list
Added to compare list
Added to compare list
Added to compare list
Added to compare list
Added to compare list
NEXT
PREV