Welcome to Uazon! Your one-stop shop for all measuring equipment.

Product Suggestions

MET ONE HHPC 6+ Particle Counter Technical Review

MET ONE HHPC 6+ Particle Counter Technical Review

Table of Contents
Technical Evaluation & Benchmarking

Beckman Coulter MET ONE HHPC 6+ Handheld Particle Counter (Model 2089311-01): Comprehensive Review

An analytical deep-dive into the portability, regulatory compliance, and metrology specifications of the industry's widely deployed 6-channel cleanroom validation instrument.

EXPERT ASSESSMENTThe Verdict

The MET ONE HHPC 6+  represents a stable standard for rapid, localized aerosol concentration monitoring. For facility managers, QA leads, and field certification technicians operating within cleanrooms (such as semiconductor fabrication, medical device packaging, or pharmaceutical compounding), this device offers a robust bridge between benchtop accuracy and true portable mobility. Its integrated charge cradle, high-capacity data retention, and standard conformity make it a highly defensible capital expenditure.

Product At a Glance

Core Parameter
Product Capability / Status
Manufacturer / Line
Beckman Coulter Met One (HHPC+ Series)
Size Channels
6 simultaneous channels (ranging from 0.3 µm to 10 µm)
Data Transfer Interface
Ethernet, USB Connection through Charge Cradle
Key Industry Compliance
ISO 14644-1:2015, 21 CFR Part 11, CE, FCC, JIS B9921

What Is the Beckman Coulter MET ONE HHPC 6+?

The MET ONE HHPC 6+ is a specialized, six-channel handheld optical particle counter configured specifically for high-technology cleanroom verification, particle source isolation, and manufacturing quality control. Airborne particulates represent a significant threat to yields in microelectronics, flat panel displays, pharmaceuticals, and optics assembly. Unlike stationary ambient monitoring systems, the handheld nature of model 2089311-01 allows technicians to systematically trace leaks, inspect filter integrity, and verify local cleanliness levels.

This specific package (2089311-01) ships with an ergonomically styled handset, a rugged transport case, and a highly functional charge cradle. The cradle is not merely a power interface; it functions as a hardware gateway, hosting physical connections for Ethernet and USB communication. This setup allows users to interface directly with regional network systems or local PCs, streamlining data extraction without requiring the operator to manage loose, fragile adapter cables on the cleanroom floor.

Deep Dive: Key Features Analyzed

Simultaneous 6-Channel Sizing

The device measures particles ranging from 0.3 to 10 µm simultaneously. This simultaneous tracking enables users to detect both fine combustion particles or chemical aerosols (near 0.3 µm) and coarse mechanically generated particles (closer to 10 µm) in a single run.

Sophisticated Cradle Communication Gateway

Data transfer is managed via an external charge cradle. When docked, the MET ONE HHPC 6+ can communicate via standard USB or Ethernet cables. This integration helps maintain stable connectivity, keeps the handset charged, and prevents field dropouts during large-scale diagnostics.

Rigorous Standards Conformity

Designed for highly regulated environments, the instrument complies with ISO 14644-1:2015 cleanroom classification standards. Additionally, with electronic records under FDA jurisdiction, its data output structures support requirements associated with 21 CFR Part 11, alongside fundamental CE and FCC certifications.

Long-Life Lithium-Ion Power Unit

Battery life is optimized for full-shift inspection routines. Typical intermittent usage delivers 10+ hours of run-time, while demanding continuous sampling runs for a minimum of 5.5 hours. A fast charging cycle restores full power via the cradle in just 3.5 hours.

Complete Technical Specifications

Specification Parameter Verified Technical Value
Platform Classification APC Instruments
Particle Size Analysis Range 0.3 to 10 µm
Sample Volume 10 µm
Onboard Data Storage 10,000 records
Battery Operating Time 10+ hours (typical intermittent use) / 5.5 hours minimum (continuous sampling)
Coincidence Loss 10% at 4,000,000 particles/ft³
Throughput (Flow Rate) 2.83 Liters per minute
Battery Chemistry Lithium Ion (rechargeable)
Battery Recharge Time 3.5 hours
Pump Accuracy & Repeatability ±5% Flow Rate
Zero Count standard Conforms to JIS B9921 (1 count or less in 5 min, 95% UCL)
Counting Efficiency 50% at 0.3 µm (100% for particles > 0.45 µm)
Count Alarms & Cycle Modes Raw counts: N/CF, N/CM, N/L in cumulative/differential modes; user-defined alarm counts
Operating Modes Semi-automated, manual, operator controlled
Screen Resolution 320 x 240 pixels
Physical Dimensions 27 cm (W) x 5.3 cm (H) x 10 cm (D)
Net Weight 0.7 kg
Device Enclosure Color Gray
Power Requirements 1.0 A, 100-240 VAC, 50/60 Hz
Client PC Interface Support Windows IE, Safari, Firefox web interfaces
Location Labels Alphanumeric Location Names

Industrial Applications

Industrial instrumentation must perform reliably under strict plant protocols. Here is how the MET ONE HHPC 6+ functions across different technical sectors:

Semiconductor Fabrication

Even sub-micron particulate deposition can ruin silicon wafers. The 0.3 µm sensitivity threshold is key for monitoring localized clean enclosures and tool microenvironments.

Medical Device Packaging

Maintains verification records compliant with ISO Class 5 through Class 8 standards. Technicians can use the handheld wand to sweep sealing zones and identify air-handling anomalies.

Aerospace Assemblies

Protects sensitive optical payloads, lens systems, and micro-sensors from particulate accumulation during critical component integrations.

Pharmaceutical Quality Control

The device supports regulatory compliance, conforming to 21 CFR Part 11 for data management and security audit protocols.

Operational Benefits

  • Streamlined ISO Classification: Speeds up verification processes under ISO 14644-1:2015, helping facilities confirm compliance with standard regulatory requirements.
  • Minimized Data Entry Errors: Alphanumeric location labeling allows technicians to map measurements directly to specific locations on the cleanroom floor, reducing the risk of clerical mix-ups.
  • Extended On-Site Diagnostics: With a 10,000-record internal memory, operators can run continuous testing shifts without needing to frequently stop and clear or download logged data.
  • Reduced Calibration Setup Overheads: Built-in pump accuracy and repeatable ±5% flow-rate systems help keep downstream operational drift to a minimum.

Critical Analysis: Pros & Cons

Key Advantages

  • Lightweight hand unit weighing only 0.7 kg reduces physical fatigue.
  • Comprehensive six-channel scanning offers data across a wider range of sizes.
  • Integrated docking station manages both battery charging and network connections.
  • Long-life battery delivers over 10 hours of typical intermittent operation.
  • Complies with 21 CFR Part 11 database and electronic record security guidelines.

Technical Constraints

  • A 10% coincidence loss at 4,000,000 particles/ft³ requires careful handling in high-concentration zones.
  • Optimized for cleanrooms rather than general environmental monitoring outside.
  • Web management features are optimized for specific traditional browsers.

What’s Included in the Box

Product Package Configuration (Product No. 2089311-01):

  • MET ONE HHPC 6+ Handheld Instrument: Configured for 6-channel aerosol monitoring (0.3 to 10 µm range).
  • Rugged Transit Case: Heavy-duty carrying case to protect the optical sensor during transit.
  • Charge & Communication Cradle: Base station featuring active power charging, plus integrated USB and Ethernet routing ports.

Buying Guidance: Who is This Instrument For?

Investing in high-end air particle instruments requires careful matching with operational needs. The MET ONE HHPC 6+ (2089311-01) is recommended for:

  • Cleanroom Validation Professionals: Those certifying facilities according to ISO Class 5 (or lower) standards who need a lightweight, six-channel portable tool.
  • HVAC & Filtration Engineers: Maintenance teams inspecting high-efficiency particulate air (HEPA) filter banks, looking for localized leaks or seal failures.
  • B2B Buyers in Regulated Manufacturing: Compliance managers in medical packaging, semiconductor production, or sterile compounding who need standard conformity and secure data-logging.

ملخص فني (Technical Summary)

يُعد راسم الإشارة (Oscilloscope) من سلسلة GW Instek GDS-2000E نقلة نوعية في أدوات القياس الهندسية. بفضل تقنية VPO (Visual Persistence Oscilloscope) المتقدمة، يمنح الجهاز المهندسين قدرة فائقة على تتبع الإشارات العشوائية والاضطرابات التي يصعب رصدها في أجهزة القياس التقليدية. يتميز الجهاز بميزات ذكية مثل "مفتاح الصفر" (Zero Key) لتسريع عملية الضبط، وذاكرة مجزأة (Segmented Memory) لتحليل دقيق للأحداث المتكررة. إنه الخيار الأمثل للمختبرات التي تسعى للموازنة بين الدقة العالية والتكلفة التشغيلية المناسبة.

WhatsApp Inquiry

Get Price & Stock Instantly

Need this product or a similar model? Send us a WhatsApp message and our sales team will assist you quickly.

Get Price & Stock on WhatsApp / استعلام السعر والتوفر واتساب

Even if the product is not listed on the website, our sales team will contact you quickly.

حتى إذا لم يكن المنتج موجودًا على الموقع، سيتواصل معك فريق المبيعات بسرعة.

FAQs

It is a high-precision, 6-channel handheld particle counter designed for cleanroom validation, filter integrity testing, and localized particle monitoring in semiconductor and pharmaceutical environments.
Yes, the device is fully compliant with ISO 14644-1:2015 standards and supports 21 CFR Part 11 requirements for secure electronic records and data logging.
The unit includes a smart charging cradle equipped with physical Ethernet and USB ports, allowing for straightforward data export to your PC via a web browser interface.
The instrument supports over 10 hours of typical intermittent operation and provides a minimum of 5.5 hours during continuous sampling cycles, fully recharging in approximately 3.5 hours.
As an authorized distributor, we handle all procurement, technical support, and calibration inquiries. Please contact us through our portal, and we will reply within one business day.