finale bevestiging van ondersteuning word vereis. Sodra u bestelling geplaas is, wag asseblief vir finale bevestiging van die maatskappy. ( 97144476031)
Fluke FLUKE-1555 FC KIT Specifications | |
Electrical Specifications | The tester's accuracy is specified for one year after calibration at operating temperatures of 0 to 35°C |
For operating temperatures outside the range (-20 to 0°C and 35 to 50°C), add ±0.25% per °C, except on the 20% bands add ±1% per °C | |
Insulation Resistance Measurement | |
250 V | Range: |
<250 kΩ | |
250 kΩ to 5 GΩ | |
5 to 50 GΩ | |
>50 GΩ | |
Accuracy (± reading): | |
Unspecified | |
5% | |
20% | |
Unspecified | |
500 V | Range: |
<500 kΩ | |
500 kΩ to 10 GΩ | |
10 to 100 GΩ | |
>100 GΩ | |
Accuracy (± reading): | |
Unspecified | |
5% | |
20% | |
Unspecified | |
1000 V | Range: |
<1 MΩ | |
1 MΩ to 20 GΩ | |
20 to 200 GΩ | |
>200 GΩ | |
Accuracy (± reading): | |
Unspecified | |
5% | |
20% | |
Unspecified | |
2500 V | Range: |
<2.5 MΩ | |
2.5 MΩ to 50 GΩ | |
50 to 500 GΩ | |
>500 GΩ | |
Accuracy (± reading): | |
Unspecified | |
5% | |
20% | |
Unspecified | |
5000 V | Range: |
<5 MΩ | |
5 MΩ to 100 GΩ | |
100 GΩ to 1 TΩ | |
>1 TΩ | |
Accuracy (± reading): | |
Unspecified | |
5% | |
20% | |
Unspecified | |
10,000 V | Range: |
<10 MΩ | |
10 MΩ to 200 GΩ | |
200 GΩ to 2 TΩ | |
>2 TΩ | |
Accuracy (± reading): | |
Unspecified | |
5% | |
20% | |
Unspecified | |
Bar Graph Range | 0 to 1 TΩ |
Insulation Test Voltage Accuracy | -0%, +10% at 1 mA load current |
Induced AC Mains Current Rejection | 2 mA maximum |
Capacitive Load | Charging rate: 5 seconds per µF |
Discharge rate: 1.5 seconds per µF | |
Leakage Current Measurement | Range: 1 nA to 2 mA |
Accuracy: ±(5% + 2 nA) | |
Capacitance Measurement | Range: 0.01 to 15 µF |
Accuracy: ±(15% rdg + 0.03 µF) | |
Timer | Range: 0 to 99 minutes |
Resolution setting: 1 minute | |
Resolution indication: 1 second | |
Live Circuit Warning | Warning range: 30 to 660 V AC/DC, 50/60 Hz |
Voltage accuracy: ±(15% + 2 V) | |
General Specifications | |
Software | FlukeView Forms™ basic software requires a PC running Windows XP, Vista, 7, or 8 |
Display | 2.9 x 4" (75 x 105 mm) |
Power | 12 V lead-acid rechargeable battery, Yuasa NP2.8-12 |
Charger input (AC): 85 to 250 V AC 50/60 Hz 20 VA | |
Environmental | Operating temperature: -4 to 122°F (-20 to 50°C) |
Storage temperature: -4 to 149°F (-20 to 65°C) | |
Humidity: 80% to 31°C decreasing linearly to 50% at 50°C | |
Altitude: 6561.68' (2000 m) | |
Enclosure sealing: IP40 | |
Input Overload Protection | 1000 V AC |
EMC | EN 61326 |
Safety Compliance | IEC 61010-1: Overvoltage category II, Pollution Degree 2 |
IEC 61010-2-030: Measurement 600 V CAT IV/1000 V CAT III | |
IEC 61557-1, IEC 61557-2 | |
Dimensions | 10.6 x 10.9 x 6.3" (269 x 277 x 160 mm) |
Weight | 8.2 lbs (3.7 kg) |