Uazon Meetgereedskap Verskaffer
00971 44476031
00971 44476031
uazon logo
0

Produk bladsy

finale bevestiging van ondersteuning word vereis. Sodra u bestelling geplaas is, wag asseblief vir finale bevestiging van die maatskappy. ( 97144476031)

Fluke Norma 6004 Portable Power Analyzer

0.00 AED
In stock
Product Details
Brand: Fluke
Number of Inputs: 4 Voltage + 4 Current
Measurement Range: 10 V, 100 V, 1000 V
Bandwidth: 1000V range: 500kHz; 100V range: 200 kHz; 10V range:100 kHz
Frequency: 100 kHz
Sampling Rate: 200ks/s
Dimensions: 298mm x 215m x 96mm
Weight: 3.5 kg (7.7 lbs)
Memory : 32GB
Operating Temperature: -10 °C to +50 °C
Storage Temperature: -30 °C to +60 °C
Interfaces: USB/RS485
Display: 5.7 inch, TFT LCD, 640x480
Power : BP 291, 10.8V/5000mAh, 54Wh IEC 62133, UN38.3

Fluke Norma 6004 Portable Power Analyzer

The Fluke 6004 is an advanced portable power analyzer from the Norma 6000 series, designed for electrical professionals across various industries. This four-channel device offers exceptional accuracy, versatility, and user-friendly features for analyzing complex electrical systems.

Key features

  • Four-channel measurement (4 voltage + 4 current inputs)
  • 0.1% base accuracy
  • Wide measurement range (up to 1000V and 10A directly)
  • 5.7-inch high-resolution TFT LCD display
  • Durable design for field use
  • 10-hour battery life
The Fluke 6004 serves multiple industries, including industrial maintenance, renewable energy, utilities, research and development, and data centers. It's ideal for tasks like troubleshooting power systems, analyzing solar inverters and wind turbines, conducting energy audits, and monitoring power consumption in computing environments.
User-friendly features include an intuitive interface, quick setup, and powerful PC software for in-depth analysis and reporting. The device is also expandable with accessories like high-voltage probes, current clamps, and specialized probes for extended measurement ranges and specific applications.

Fluke Norma 6004 Specifications

Inputs Norma 6003 3 Voltage + 3 Current
Norma 6003+ 3 Voltage + 3 Current + 1 Motor
Norma 6004 4 Voltage + 4 Current
Norma 6004+ 4 Voltage + 4 Current + 1 Motor
Sample rate 200ks/s
Measurement update rate 100ms, 200ms, 500ms, 1s
Dimensions (H * W * L) 298mm x 215m x 96mm
Weight 3.5 kg (7.7 lbs)
Display 5.7 inch, TFT LCD, 640x480
Operating temperature -10 °C to +50 °C
Storage temperature -30 °C to +60 °C
Operating humidity Non-condensing (< 10 °C )
≤ 90 % RH (at 10 °C to 30 °C)
≤ 75 % RH (at 30 °C to 40 °C)
≤ 45 % RH (at 40 °C to 50 °C)
Operating altitude 2000m
Storage altitude 12000m
Ingress protection IP 50 (Terminals mated) according to IEC 60529:
Battery BP 291, 10.8V/5000mAh, 54Wh IEC 62133, UN38.3
Operating time: 10 Hours (on battery)
Safety IEC 61010-1: Pollution Degree 2
IEC 61010-2-030: CAT IV 600V, CAT III 1000 V
EMC IEC 61326-1: Industrial
IEC 61326-2-2
Warranty 1 Year
Communication Interface USB/RS485
Dual Analyzer Synchronization Mode Able to extend to 6, 7 or 8 channels (using multiple instruments)
PC Software Fluke Power Analyzer software
Storage Capacity 32GB
Data trend storage rate As per display rate
Main Function Meter, Scope, Harmonic, Phasor, Trend
Measuring Parameters RMS, DC Component, AC Component, Rectified Mean, Peak Value, Peak-Peak, Crest Factor, Form Factor, Fundamental Component, Fundamental Content, Harmonic Distortion, Harmonic Content, Harmonic Factor for voltages and currents, Active Power, Reactive Power, Apparent Power, Power Factor, Phase Shift, Efficiency, Impedance, Electric Energy, Charge/Discharge capacity (Ah), Frequency, Motor Speed, Torque, Mechanical Power, Mechanical Energy, Summation function
Electrical Specifications
Voltage
Range 10 V, 100 V, 1000 V
Crest Factor CF ≤ 2
Maximum Voltage 10 % overload
Input Impedance 2M Ω/10pF (Typical)
Temperature Coefficient 0.05 * (Spec)/k
Bandwidth 1000V range: 500kHz; 100V range: 200 kHz; 10V range:100 kHz
CMRR 120 dB @ 50/60 Hz
Accuracy (% reading + % range)
Range 1000 V 100 V 10 V
DC 0.1 + 0.1 0.1 + 0.1 0.1 + 0.2
AC (10Hz to 1kHz) 0.1 + 0.1 0.1 + 0.1 0.1 + 0.2
AC (10kHz) 5 + 0.5 5 + 0.5 5 + 0.5
Current
Crest Factor CF ≤ 2
Temperature Coefficient 0.05 x (Spec)/k
Overload capacity 10 % overload
CMRR 120 dB @ 50/60 Hz
Shunt (current input)
Measuring Range 0.1 A, 1 A, 10 A
Input Impedance 0.025 Ω (Typical)
Bandwidth 10 A range: 500 kHz; 1 A range: 200 kHz; 0.1 A range: 100 kHz
BNC (voltage input)
Range 0.1 V, 1 V, 10 V
Input Impedance 100k Ω/100pF (Typical)
Bandwidth 10 V range: 500 kHz; 1 V range: 200 kHz; 0.1 V range: 100 kHz
Accuracy (% reading + % range)
Range 10 A 1 A 0.1 A 10 V 1 V 0.1 V
DC 0.1 + 0.2 0.1 + 0.5 0.1+2 0.1+0.1 0.1+0.2 0.1+1
AC (10Hz to 1kHz) 0.1+0.1 0.1+0.2 0.1+1 0.1+0.1 0.1+0.1 0.1+0.5
AC (10kHz) 5+1 5+1 5+1 5+1 5+1 5+1
Motor Module (Torque and Speed)
Voltage Range ± 10 V dc, 10 % overload
Voltage Channels 2
Input Impedance 1.1M Ω (Typical)
Accuracy at dc 0.1 % range + 0.1 % reading
Pulse Channels 3
Pulse Logic High Threshold 2 V (Typical)
Pulse Logic Low Threshold 0.8 V (Typical)
Maximum Pulse Frequency 100 kHz
Motor Module (Torque and Speed)
Frequency Accuracy 0.05 % range + 0.05 % reading
Harmonics 100 (50Hz/60Hz)
Calculation method FFT/Interpolation
Save this product for later
Share this product with your friends
Fluke Norma 6004 Portable Power Analyzer
Share by:
document.addEventListener("DOMContentLoaded", function() { const observer = new MutationObserver(function() { const products = document.querySelectorAll(".details-product-price__value.ec-price-item.notranslate"); products.forEach(function(priceElement) { if (parseFloat(priceElement.textContent) === 0) { priceElement.textContent = "Call for Best Price\n00971(04) 447 6031\n00971(04) 344 9868"; } }); }); observer.observe(document.body, { childList: true, subtree: true }); });