finale bevestiging van ondersteuning word vereis. Sodra u bestelling geplaas is, wag asseblief vir finale bevestiging van die maatskappy. ( 97144476031)
Fluke 1662 Multifunction Tester stand out as solid, reliable tools designed for electrical installation testing. These testers are known for their versatility and ease of use, making them a popular choice among professionals in the field. In this article, we will delve into the key features and functionalities that make the Fluke 1662 a go-to solution for testing electrical installations.
Fluke 1662 Multifunction Testers offer a range of essential features, making them invaluable for electricians and technicians. These testers can measure voltage and frequency, providing crucial information about the electrical system's health.
Additionally, they check wiring polarity to detect broken N wires and measure insulation resistance, offering a comprehensive evaluation of the installation's integrity.
AC voltage measurement | ||||
Range | 500 V | |||
Resolution | 0.1 V | |||
Accuracy 45 Hz – 66 Hz | 0.8% + 3 | |||
Input impedance | 360 kΩ | |||
Overload protection | 660 V rms | |||
Continuity testing (RLO) | ||||
Range (autoranging) | 20 Ω / 200 Ω / 2000 Ω | |||
Resolution | 0.01 Ω / 0.1 Ω / 1 Ω | |||
Open Circuit Voltage | >4 V | |||
Insulation resistance measurement (RISO) | ||||
Accuracy of test voltage (at rated test current) | +10%, -0% | |||
Test voltage | 100 V | |||
250 V | ||||
500 V | ||||
1000 V | ||||
Insulation resistance range | 20 MΩ / 50 MΩ | |||
20 MΩ / 100 MΩ | ||||
20 MΩ / 200 MΩ | ||||
20 MΩ / 200 MΩ / 500 MΩ | ||||
20 MΩ / 200 MΩ / 1000 MΩ | ||||
Resolution | 0.01 MΩ / 0.1 MΩ | |||
0.01 MΩ / 0.1 MΩ | ||||
0.01 MΩ / 0.1 MΩ | ||||
0.01 MΩ / 0.1 MΩ / 1 MΩ | ||||
0.01 MΩ / 0.1 MΩ / 1 MΩ | ||||
Test current | 1 mA @ 50 kΩ | |||
1 mA @ 100 kΩ | ||||
1 mA @ 250 kΩ | ||||
1 mA @ 500 kΩ | ||||
1 mA @ 1 MΩ | ||||
Loop and line impedance (ZI) | ||||
Range | 10 Ω / 0.001 Ω / High current mΩ mode | |||
Resolution | 0.01 Ω / 0.1 Ω / 1 Ω | |||
Prospective earth fault current, PSC test | ||||
Range | 1000 A / 10 kA (50 kA) | |||
Resolution | 1 A / 0.1 kA | |||
Computation | Prospective earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively. | |||
RCD testing, RCD types tested | ||||
RCD Type | A 4 , AC¹, G², S³ | |||
Notes | ¹Responds to AC | |||
²General, no delay | ||||
³Time delay | ||||
4 Responds to pulsed signal | ||||
5 Responds to smooth DC signal | ||||
Tripping speed test (ΔT) | ||||
Current settings¹ | 10-30-100-300-500-1000 mA – VAR | |||
10-30-100 mA | ||||
Multiplier | x ½, x 1 | |||
x 5 | ||||
Measurement range | RCD Type G | 310 ms | ||
50 ms | ||||
RCD Type S | 510 ms | |||
160 ms | ||||
Notes | ¹1000 mA type AC only | |||
700 mA maximum type A in VAR mode | ||||
VAR mode not available for type B. | ||||
RCD/FI-Tripping Current Measurement/Ramp Test (IΔN) | ||||
Current range | 30% to 110% of RCD rated current¹ | |||
Step size | 10% of IΔN² | |||
Dwell time | Type G | 300 ms/step | ||
Type S | 500 ms/step | |||
Measurement accuracy | ±5% | |||
Specified trip current ranges (EN 61008-1) | 50% to 100% for Type AC | |||
35% to 140% for Type A (>10 mA) | ||||
35% to 200% for Type A (≤10 mA) | ||||
50% to 200% for Type B | ||||
²5% for Type B | ||||
Notes | ¹30% to 150% for Type A IΔN > 10 mA | |||
30% to 210% for Type A IΔN = 10 mA | ||||
20% to 210% for Type B | ||||
Phase Sequence Indication | ||||
Icon |
|
|||
General Specifications | ||||
Size (L x W x H) | 10 x 25 x 12.5 cm | |||
Weight (incl. batteries) | 1.3 (kg) | |||
Battery size, quantity | Type AA, 6 ea. | |||
Sealing | IP-40 | |||
Safety | Complies with EN/IEC 61010-1 and EN/IEC 61010-2-034 | |||
Overvoltage | CAT III / 500V; CAT IV 300V | |||
Performance | EN61557-1 to EN61557-7 and EN61557-10 |