Fluke 124B Industrial ScopeMeter handheld Oscilloscopes
0.00 AED
In stock
Product Details
Brand:
Fluke
Bandwidth:
20 MHz
Number of channels:
2
sample rate:
400 K samples
sensitivity:
5 mV to 200 V/div
Measurements:
DC voltage (VDC), True-rms voltages (V ac and V ac+dc), Frequency (Hz), Peak, Duty cycle (PULSE), RPM, Pulse width (PULSE), Amperes (AMP), Temperature (TEMP) with optional temperature probe
Memory:
400 M samples Recorded Time
Display:
5.7-inch color active matrix TFT
Operating temperature:
0 to 40 °C (32 to 104 °F)
Storage Temperature:
-20 to 60 °C (-4 to 140 °F)
Operating altitude:
Operating at 3 km (10,000 feet)
Size:
259 x 132 x 55 mm (10.2 x 5.2 x 2.15 in)
Weight:
1.4 kg (3.2 lb) including battery pack
Power:
Input voltage: 10 to 21 V DC Consumption: 5 W typical, Battery power: Rechargeable Li-Ion 10.8 V
Fluke 124B Industrial ScopeMeter handheld Oscilloscopes
In today's highly dynamic industrial environment, precise and reliable measuring instruments are essential for professionals across a range of fields. Fluke, a renowned provider of electronic testing equipment, offers a solution in the form of the Fluke 124B Industrial Handheld Oscilloscopes. These versatile devices are designed to meet the demands of professionals working in various industries, enabling them to make accurate measurements on the go.
Portability and Durability
One of the key features of the Fluke 124B is its handheld design, which allows engineers and technicians to easily carry and use it wherever they go. Its compact size, combined with a rugged outer casing, ensures that the oscilloscope can withstand the rigors of the industrial environment. With the Fluke 124B in hand, professionals can effortlessly move around a facility to troubleshoot and measure electronic signals.
Intuitive User Interface
The User Interface (UI) of the Fluke 124B is designed with simplicity and ease of use in mind. The clear display, combined with a responsive touchscreen, makes navigating through the different functions and settings a breeze. Even for users who are unfamiliar with oscilloscopes, the intuitive UI enables quick and efficient measurements without the need for extensive training.
Advanced Signal Analysis
The Fluke 124B is equipped with a variety of signal analysis features that help professionals gain deeper insights into the characteristics of electronic signals. Built-in functions such as Automatic Measurements, Peak Detect, and Persistence Mode allow users to analyze waveforms and identify anomalies with precision. The ability to capture, store, and recall waveforms provides additional flexibility for in-depth analysis and comparison.
Connectivity and Compatibility
To facilitate seamless integration into existing systems and workflows, the Fluke 124B comes with multiple connectivity options. With USB and Ethernet ports, professionals can easily transfer captured data to a computer for further analysis or share it with colleagues or clients. Furthermore, the oscilloscope is compatible with a wide range of software applications, allowing users to export data in various formats according to their specific requirements.
Safety and Compliance
Compliance with safety standards is a top priority when working with any electronic measuring device. Fluke ensures that the 124B meets the industry's safety standards, giving professionals peace of mind when using the device in hazardous environments. The oscilloscope's robust construction, reinforced insulation, and proper grounding ensure maximum safety, making it a reliable tool for demanding industrial applications.
Fluke 124B Specifications
Category | Specification |
Oscilloscope Mode (Vertical) | |
Frequency Response - DC Coupled | Without probes and test leads (with BB120): DC to 40 MHz (-3 dB) |
With VP41 10:1 probe: DC to 40 MHz (-3 dB) | |
With STL120-IV 1:1 shielded test leads: DC to 12.5 MHz (-3 dB), DC to 20 MHz (-6 dB) | |
Frequency Response - AC Coupled (LF Roll Off) | Without probes and test leads: <10 Hz (-3 dB) |
With STL120-IV 1:1 shielded test leads: <10 Hz (-3 dB) | |
With VP41 10:1 probe: <10 Hz (-3 dB) | |
Rise Time, Excluding Probes, Test Leads | <8.75 ns |
Input Impedance | Without probes and test leads: 1 MΩ/20 pF |
With BB120: 1 MΩ/24 pF | |
With STL120-IV 1:1 shielded test leads: 1 MΩ/230 pF | |
With VP41 10:1 probe: 5 MΩ/15.5 pF | |
Sensitivity | 5 mV to 200 V/div |
Analog Bandwidth Limiter | 10 kHz |
Display Modes | A, -A, B, -B |
Maximum Input Voltage A and B | Direct, with test leads, or with VP41 probe: 600 Vrms CAT IV, 750 Vrms maximum voltage |
With BB120: 600 Vrms | |
Maximum Floating Voltage | From any Terminal to Ground: 600 Vrms CAT IV, 750 Vrms up to 400 Hz |
Oscilloscope Mode (Horizontal) | |
Scope Modes | Normal, single, roll |
Ranges (Normal) | Equivalent sampling: 20 ns to 500 ns/div |
Real time sampling: 1 μs to 5 s/div | |
Single (real time): 1 μs to 5 s/div | |
Roll (real time): 1 s to 60 s/div | |
Sampling Rate (for Both Channels Simultaneously) | Equivalent sampling (repetitive signals): up to 4 GS/s |
Real time sampling 1 μs to 60 s/div: 40 MS/s | |
Trigger | Screen Update: Free run, on trigger |
Source | A, B |
Sensitivity A and B | At DC to 5 MHz: 0.5 divisions or 5 mV |
At 40 MHz: 1.5 divisions | |
At 60 MHz: 4 divisions | |
Slope | Positive, negative |
Advanced Scope Functions | |
Display Modes | Normal: Captures up to 25 ns glitches and displays analog-like persistence waveform |
Smooth: Suppresses noise from a waveform | |
Glitch off: Does not capture glitches between samples | |
Envelope: Records and displays the minimum and maximum of waveforms over time | |
Auto Set (Connect-and-View) | Continuous fully automatic adjustments of amplitude, time base, trigger levels, trigger gap, and hold-off. Manual override by user adjustment of amplitude, time base, or trigger level |
General Specifications | |
Waveform Display | Vertical: 10 div of 40 pixels |
Horizontal: 12 div of 40 pixels | |
Maximum Input Voltage A and B | Direct on input or with leads: 600 Vrms CAT IV for derating |
With banana-to BNC adapter BB120: 600 Vrms for derating | |
Maximum Floating Voltage | From any terminal to ground: 600 Vrms CAT IV, 750 Vrms up to 400 Hz |
Display Type | 5.7" color active matrix TFT |
Resolution | 640 x 480 |
Interface | Optically isolated: Transfer screen copies (bitmaps), settings and data |
USB to PC/laptop: OC4USB optically isolated USB adapter/cable, (optional), using FlukeView® software for Windows® Wireless Radio with Adapter Frequency range: 2412 to 2462 MHz | |
Wireless Radio with Adapter | Frequency range: 2412 to 2462 MHz |
Output power: <100 mW | |
Environmental | MIL-PRF-28800F, Class 2 |
Temperature | Battery operation: 32 to 104°F (0 to 40°C) |
Power adapter operation: 32 to 122°F (0 to 50°C) | |
Storage: -4 to 140°F (-20 to 60°C) non-condensing | |
Humidity (Operating) | At 32 to 50°F (0 to 10°C): non-condensing |
At 50 to 86°F (10 to 30°C): 95% | |
At 86 to 104°F (30 to 40°C): 75% | |
At 104 to 122°F (40 to 50°C): 45% | |
Altitude | Operating at 10,000' (3 km): CAT III 600 V |
Operating at 6600' (2 km): CAT IV 600 V | |
Storage: 40,000' (12 km) | |
EMC Electromagnetic Compatibility | USA (FCC): 47 CFR 15 subpart B (this product is considered an exempt device per clause 15.103) |
Enclosure Protection | IP51, ref: EN/IEC60529 |
Safety General | IEC 61010-1: Pollution Degree 2 |
Measurement | IEC 61010-2-033: CAT IV 600 V/CAT III 750 V |
Memory | Internal memory can store 20 data sets (screen waveform and setup) |
Micro SD card slot with optional SD card (maximum size of 32 GB) | |
Power | External: Via power adapter BC430 |
Input voltage: 10 to 21 V DC Consumption: 5 W typical | |
Input connector: 5 mm jack | |
Internal: Via battery pack BP290 | |
Battery power: Rechargeable Li-Ion 10.8 V | |
Operating time: 7 hours with 50 % backlight brightness | |
Charging time: 4 hours with test tool off, 7 hours with test tool on | |
Allowable ambient temperature: 32 to 104°F (0 to 40°C) during charging | |
Dimensions | 10.2 x 5.2 x 2.15" (259 x 132 x 55 mm) |