  • Temperature measurement range from -200 °C to +1370 °C with Type K thermocouple and -40 °C to +150 °C with NTC sensor.
  • High precision accuracy down to ±0.05 hPa for differential pressure and ±0.3 °C for temperature.
  • High resolution display: 0.1 °C for temperature and 0.01 hPa for pressure.
Added to compare list
Order above 500 AED = Free Delivery
Delivery by * within UAE. When you order in
This item will be delivered by .
Want it Tomorrow?
Select Click & Collect on checkout within the next
We are not Supporting COD Payments Terms Outside UAE
Secure Transaction
This item is eligible for return
Online support
24/7 Support
Original Products
quality guarantee
Fast Delivery
Fastest delivery ever!
Online payment
fast and safe
secure and live track
fast and safe
Description

About this model

Buy Testo 440 dP: Advanced Air Velocity and IAQ Measurement

The Testo 440 dP multifunction measuring instrument represents a significant upgrade in the field of air velocity and indoor air quality (IAQ) testing. Designed for HVAC technicians, industrial hygienists, and facility managers, this handheld device integrates a built-in differential pressure sensor, offering a broader range of measurement capabilities than standard anemometers. By combining a robust handheld unit with intelligent probe technology, the Testo 440 dP simplifies complex tasks such as filter monitoring, K-factor determination, and long-term IAQ logging. For professionals seeking accuracy, versatility, and ease of use, finding the best price for the Testo 440 dP is an investment in streamlined daily operations.

Technical Features and Field Applications of the Testo 440 dP (0560 4402)

The core strength of the Testo 440 dP lies in its ability to handle multiple applications without requiring a fleet of different instruments. The device utilizes auto probe detection, which automatically identifies connected sensors and adjusts the measurement menu accordingly. This feature significantly reduces setup time and eliminates manual errors during field inspections. Whether you are performing in-duct measurements or monitoring cleanroom conditions, the Testo 440 dP provides a structured interface that guides the user through every step.

  • Versatile Probe Connectivity: The instrument supports up to three probes operating simultaneously. You can connect a Bluetooth probe for wireless convenience, a standard wired probe via the universal handle, and a type K thermocouple for temperature readings. This flexibility allows for comprehensive parameter recording without constantly switching cables.
  • Built-in Differential Pressure Sensor: Unlike standard anemometers, the Testo 440 dP features an integrated differential pressure sensor. This allows for precise measurements on filters and fans, as well as calculations for volume flow using K-factors and Pitot tubes (Pitot tubes sold separately).
  • Clear Data Visualization: The large graphic display shows three readings simultaneously, ensuring that critical data is visible at a glance. The internal memory can store up to 7,500 measurement protocols, which can be easily exported via the USB port for further analysis in CSV format.

Wireless Convenience and Ergonomic Design of 0560 4402

Reducing cable clutter is essential for efficient workflow and safety on job sites. The Testo 440 dP utilizes Bluetooth technology to transmit readings from compatible probes up to a distance of 20 meters. This wireless capability is particularly beneficial for high-altitude measurements or hard-to-reach ventilation grilles. For environments where Bluetooth signals are restricted, the device also supports a wired cable handle option, ensuring that you never have to compromise on connectivity.

  • Universal Handle System: One handle fits all probes, allowing technicians to master more applications using fewer devices. This modular approach saves space in the measurement case and reduces the overall equipment weight.
  • Optimized for Mobile Work: The ergonomic design ensures comfortable handling during long-term measurements. The inclusion of 3 AA batteries ensures reliable operation in the field without the need for proprietary battery packs.
  • On-Site Reporting: With the optional Testo BLUETOOTH/IRDA printer, professionals can generate hardcopy reports directly at the facility, providing immediate documentation for clients or compliance audits.

Indoor Air Quality and Long-Term Monitoring Capabilities

Ensuring healthy indoor environments requires precise long-term monitoring of CO2, CO, humidity, and temperature. The Testo 440 dP is engineered specifically to support these demanding applications. The intuitive measurement menus simplify the setup for long-term logging, allowing users to input duration parameters and let the device run autonomously throughout the day. This capability is vital for assessing ventilation system performance and detecting potential mold risks or high CO2 levels in office buildings, schools, and industrial facilities.

  • Comprehensive IAQ Probe Options: The system is compatible with a wide range of high-precision probes, including CO2, CO, air temperature, and humidity sensors. These are available in both Bluetooth and fixed-cable variants to suit different operational preferences.
  • Internal Data Storage: With a capacity for 7,500 measurement protocols, the Testo 440 dP allows for extensive data collection over time without the need for constant data offloading. This ensures that historical trends are captured accurately for compliance reporting.
  • Standardized Turbulence Measurement: The device features specialized
Specification
Measurement TypeMeasuring RangeAccuracyResolution
Temperature – NTC-40 °C to +150 °C±0.4 °C (-40 °C to -25.1 °C)
±0.3 °C (-25 °C to +74.9 °C)
±0.4 °C (+75 °C to +99.9 °C)
±0.5 % of mv (Remaining Range)
0.1 °C
Temperature – TC Type K-200 °C to +1370 °C±(0.3 °C + 0.3 % of mv)0.1 °C
Differential Pressure (Internal Sensor)-150 hPa to +150 hPa±0.05 hPa (0 hPa to 1.00 hPa)
±0.2 hPa + 1.5 % of mv (1.01 hPa to +150 hPa)